Megger VLF Sine Wave 34 kV
Updated 2026-10-27
Specifications
Figures as the manufacturer states them on its product page or datasheet; each row links its data record.
- Dimensions
- 520 x 450 x 300 mm (W x H x D)
- Frequency range
- 0.01 Hz to 0.1 Hz, automatic frequency adjustment
- Ingress protection
- IP 20 (operation) / IP 54 (transportation)
- Input voltage
- 100 V to 260 V, 50/60 Hz, 400 VA
- Operating temperature
- -20 °C to +55 °C
- Output current
- 0 to 14 mA, precision ±1 %, resolution 1 μA
- Output voltage dc rectangular
- DC ±0 to 34 kV; VLF rectangular 0 to 34 kV; precision ±1 %, resolution 0.1 kV
- Output voltage sine
- 0 to 24 kVRMS / 0 to 34 kVpeak
- Weight
- 25 kg
Data records
- The manufacturer's page for the VLF Sine Wave 34 kV was read on the date given in the value. Value: 2026-10-27.
- Megger lists the VLF Sine Wave 34 kV as a portable VLF sine wave test system for medium voltage cables. Value: VLF test set.
- An integrated breakdown detection function shuts down the test voltage of the VLF Sine Wave 34 kV when the charge current becomes excessive.
- The VLF Sine Wave 34 kV also performs rectangular wave and DC voltage tests.
- The VLF Sine Wave 34 kV performs cable sheath testing and, with the optional ESG NT step voltage probe, sheath fault pinpointing.
- The VLF Sine Wave 34 kV applies a very low frequency sine wave test voltage to medium voltage cables.
- The VLF Sine Wave 34 kV can serve as the voltage source for the optional tan delta measurement and partial discharge attachments.
- The VLF Sine Wave 34 kV is a product of Megger. Value: Megger.
- The manufacturer gives the model designation as VLF Sine Wave 34 kV. Value: VLF Sine Wave 34 kV.
- Megger maintains a product page for the VLF Sine Wave 34 kV on its own website, which is the page cited for this entry.
- The datasheet states the dimensions of the VLF Sine Wave 34 kV. Value: 520 x 450 x 300 mm (W x H x D).
- The datasheet states the test frequency range of the VLF Sine Wave 34 kV with automatic frequency adjustment. Value: 0.01 Hz to 0.1 Hz, automatic frequency adjustment.
- The datasheet states the protection class of the VLF Sine Wave 34 kV in operation and for transportation. Value: IP 20 (operation) / IP 54 (transportation).
- The datasheet states the mains input range and power consumption of the VLF Sine Wave 34 kV. Value: 100 V to 260 V, 50/60 Hz, 400 VA.
- The datasheet states the capacitive load the VLF Sine Wave 34 kV drives at two frequencies. Value: 0.6 μF at 0.1 Hz at 24 kVRMS; 5 μF at 0.01 Hz at 21 kVRMS.
- The datasheet states the operating temperature range of the VLF Sine Wave 34 kV. Value: -20 °C to +55 °C.
- The datasheet states the output current measuring range, precision and resolution of the VLF Sine Wave 34 kV. Value: 0 to 14 mA, precision ±1 %, resolution 1 μA.
- The datasheet states the DC and the VLF rectangular output voltage ranges of the VLF Sine Wave 34 kV. Value: DC ±0 to 34 kV; VLF rectangular 0 to 34 kV; precision ±1 %, resolution 0.1 kV.
- The datasheet states the VLF sine wave output voltage range of the VLF Sine Wave 34 kV. Value: 0 to 24 kVRMS / 0 to 34 kVpeak.
- The datasheet states the weight of the VLF Sine Wave 34 kV. Value: 25 kg.
- The datasheet names IEC 60229 as the standard for the sheath testing and sheath fault pinpointing functions of the VLF Sine Wave 34 kV and gives no edition. Value: IEC 60229.
- The catalog name of the model is written Megger VLF Sine Wave 34 kV. Value: Megger VLF Sine Wave 34 kV.
Sources
- Megger datasheet, VLF SINE 34 kV test system for medium voltage cables data sheet (VLFSinus34kV_DS_EN_V03a), web page edition, Megger. Held as: Public page. Publisher page
- Megger product page, VLF Sine Wave 34 kV - Cable Tester, web page edition, Megger. Held as: Public page. Publisher page
Changelog (44 entries)
| Date | Revision | Change |
|---|---|---|
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.checked) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.checked) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.class) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.class) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.function.breakdown-detection) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.function.breakdown-detection) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.function.dc-and-rectangular-test) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.function.dc-and-rectangular-test) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.function.sheath-testing) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.function.sheath-testing) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.function.vlf-sine-wave-test) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.function.vlf-sine-wave-test) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.function.voltage-source-for-diagnostics) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.function.voltage-source-for-diagnostics) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.manufacturer) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.manufacturer) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.model) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.model) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.product-page) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.product-page) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.spec.dimensions) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.spec.dimensions) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.spec.frequency-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.spec.frequency-range) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.spec.ingress-protection) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.spec.ingress-protection) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.spec.input-voltage) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.spec.input-voltage) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.spec.load-capacity) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.spec.load-capacity) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.spec.operating-temperature) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.spec.operating-temperature) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.spec.output-current) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.spec.output-current) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.spec.output-voltage-dc-rectangular) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.spec.output-voltage-dc-rectangular) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.spec.output-voltage-sine) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.spec.output-voltage-sine) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.spec.weight) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.spec.weight) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.standard.iec-60229) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.standard.iec-60229) | |
| 2026-10-27 | created (prod.megger-vlf-sine-wave-34-kv.title) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-vlf-sine-wave-34-kv.title) |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Megger VLF Sine Wave 34 kV." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/megger-vlf-sine-wave-34-kv/.
Test Instrument Reference, Megger VLF Sine Wave 34 kV (Oct. 27, 2026), https://www.testinstrumentreference.com/products/megger-vlf-sine-wave-34-kv/.
@misc{etr-products-megger-vlf-sine-wave-34-kv,
title = {Megger VLF Sine Wave 34 kV},
howpublished = {\url{https://www.testinstrumentreference.com/products/megger-vlf-sine-wave-34-kv/}},
organization = {Test Instrument Reference},
publisher = {Test Instrument Reference},
year = {2026},
note = {last substantive change 2026-10-27}
}{{cite web |title=Megger VLF Sine Wave 34 kV |website=Test Instrument Reference |publisher=Test Instrument Reference |url=https://www.testinstrumentreference.com/products/megger-vlf-sine-wave-34-kv/ |date=2026-10-27 |access-date=}}