Fluke 1630-2 FC, clamp on ground tester
Image: Fluke, from its product page (www.fluke.com)

Specifications

Figures as the manufacturer states them on its product page or datasheet; each row links its data record.

Frequency range
40 Hz to 1 kHz
Measurement category
CAT IV 600 V / CAT III 1000 V
Operating temperature
-10 °C to +50 °C
Weight
880 g

Data records

  • The manufacturer's page for the 1630-2 FC was read on the date given in the value. Value: 2026-10-27. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.checked
  • Fluke lists the 1630-2 FC as an earth ground clamp. Value: clamp-on ground tester. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.class
  • The 1630-2 FC accepts user-defined high and low alarm thresholds. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.function.alarm-thresholds
  • The 1630-2 FC has a selectable band-pass filter for removing noise from leakage current measurements. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.function.band-pass-filter
  • The 1630-2 FC transmits readings to the Fluke Connect mobile application over a wireless link. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.function.fluke-connect
  • The 1630-2 FC measures earth ground AC leakage current without disconnecting the earth ground stake. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.function.leakage-current
  • The 1630-2 FC logs measurements at a set interval and stores them in internal memory. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.function.logging
  • The 1630-2 FC measures earth ground loop resistance in multi-grounded systems with a dual clamp jaw, without disconnecting parallel grounds or driving auxiliary stakes. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.function.loop-resistance
  • The 1630-2 FC is a product of Fluke. Value: Fluke. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.manufacturer
  • The manufacturer gives the model designation as 1630-2 FC. Value: 1630-2 FC. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.model
  • Fluke maintains a product page for the 1630-2 FC on its own website, which is the page cited for this entry. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.product-page
  • The manufacturer states the battery type of the 1630-2 FC and a battery life in ground resistance mode with the backlight and the radio off. Value: 4 x AA alkaline IEC/EN LR6; more than 15 hours. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.spec.battery
  • The manufacturer states the dimensions of the 1630-2 FC. Value: 283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in). Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.spec.dimensions
  • The manufacturer states a frequency range for the 1630-2 FC. Value: 40 Hz to 1 kHz. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.spec.frequency-range
  • The manufacturer states an ingress protection rating for the 1630-2 FC with the jaw closed. Value: IP30 with jaw closed (IEC/EN 60529). Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.spec.ingress-protection
  • The manufacturer states an approximate conductor size for the jaw opening of the 1630-2 FC. Value: 40 mm (1.57 in) approximately. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.spec.jaw-opening
  • The manufacturer states an autoranging true-rms earth ground leakage current measuring range for the 1630-2 FC. Value: 0.200 mA to 39.99 A, true rms, 50/60 Hz. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.spec.leakage-current-range
  • The manufacturer states an earth ground loop resistance measuring range for the 1630-2 FC with an accuracy that depends on the range. Value: 0.025 Ω to 1500 Ω; ±(1.5% of reading + 0.02 Ω) in the lowest range. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.spec.loop-resistance-range
  • The manufacturer states a measurement category rating for the 1630-2 FC. Value: CAT IV 600 V / CAT III 1000 V. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.spec.measurement-category
  • The manufacturer states an operating temperature range for the 1630-2 FC. Value: -10 °C to +50 °C. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.spec.operating-temperature
  • The manufacturer states a weight for the 1630-2 FC. Value: 880 g. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.spec.weight
  • The product page names IEC 61010-1 as the general safety standard and IEC 61010-2-032 as the measurement safety standard the 1630-2 FC is built to; the page gives no edition. Value: IEC/EN 61010-1; IEC/EN 61010-2-032. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.standard.iec-61010-1
  • The product page names IEC 61326-1 as the electromagnetic compatibility standard for the 1630-2 FC in a portable environment; the page gives no edition. Value: IEC/EN 61326-1. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.standard.iec-61326-1
  • The product page names IEC 61557-13, leakage current clamps, among the standards the 1630-2 FC is built to; the page gives no edition. Value: IEC/EN 61557-13. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.standard.iec-61557-13
  • The product page names IEC 61557-5, resistance to earth, among the standards the 1630-2 FC is built to; the page gives no edition. Value: IEC/EN 61557-5. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.standard.iec-61557-5
  • The catalog name of the model is written Fluke 1630-2 FC. Value: Fluke 1630-2 FC. Source: Fluke product page, web page edition. Verified 2026-10-27. Record prod.fluke-1630-2-fc.title

Sources

  • Fluke product page, Fluke 1630-2 FC Earth Ground Clamp | Fluke, web page edition, Fluke. Held as: Public page. Publisher page
Changelog (52 entries)
DateRevisionChange
2026-10-27created (prod.fluke-1630-2-fc.checked)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.checked)
2026-10-27created (prod.fluke-1630-2-fc.class)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.class)
2026-10-27created (prod.fluke-1630-2-fc.function.alarm-thresholds)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.function.alarm-thresholds)
2026-10-27created (prod.fluke-1630-2-fc.function.band-pass-filter)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.function.band-pass-filter)
2026-10-27created (prod.fluke-1630-2-fc.function.fluke-connect)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.function.fluke-connect)
2026-10-27created (prod.fluke-1630-2-fc.function.leakage-current)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.function.leakage-current)
2026-10-27created (prod.fluke-1630-2-fc.function.logging)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.function.logging)
2026-10-27created (prod.fluke-1630-2-fc.function.loop-resistance)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.function.loop-resistance)
2026-10-27created (prod.fluke-1630-2-fc.manufacturer)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.manufacturer)
2026-10-27created (prod.fluke-1630-2-fc.model)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.model)
2026-10-27created (prod.fluke-1630-2-fc.product-page)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.product-page)
2026-10-27created (prod.fluke-1630-2-fc.spec.battery)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.spec.battery)
2026-10-27created (prod.fluke-1630-2-fc.spec.dimensions)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.spec.dimensions)
2026-10-27created (prod.fluke-1630-2-fc.spec.frequency-range)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.spec.frequency-range)
2026-10-27created (prod.fluke-1630-2-fc.spec.ingress-protection)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.spec.ingress-protection)
2026-10-27created (prod.fluke-1630-2-fc.spec.jaw-opening)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.spec.jaw-opening)
2026-10-27created (prod.fluke-1630-2-fc.spec.leakage-current-range)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.spec.leakage-current-range)
2026-10-27created (prod.fluke-1630-2-fc.spec.loop-resistance-range)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.spec.loop-resistance-range)
2026-10-27created (prod.fluke-1630-2-fc.spec.measurement-category)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.spec.measurement-category)
2026-10-27created (prod.fluke-1630-2-fc.spec.operating-temperature)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.spec.operating-temperature)
2026-10-27created (prod.fluke-1630-2-fc.spec.weight)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.spec.weight)
2026-10-27created (prod.fluke-1630-2-fc.standard.iec-61010-1)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.standard.iec-61010-1)
2026-10-27created (prod.fluke-1630-2-fc.standard.iec-61326-1)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.standard.iec-61326-1)
2026-10-27created (prod.fluke-1630-2-fc.standard.iec-61557-13)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.standard.iec-61557-13)
2026-10-27created (prod.fluke-1630-2-fc.standard.iec-61557-5)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.standard.iec-61557-5)
2026-10-27created (prod.fluke-1630-2-fc.title)
2026-10-27review_status unreviewed -> software_reviewed (prod.fluke-1630-2-fc.title)

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Fluke 1630-2 FC." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/fluke-1630-2-fc/.