Figures as the manufacturer states them on its product page or datasheet; each row links its data record.
- Ingress rating
- IP32
- Input voltage
- 90 to 264 V (50/60 Hz), max. 70 VA
- Oil temperature range
- 0 to 99 °C, resolution 1 °C
- Operating temperature
- -10 °C to +55 °C
- Output voltage
- 0 to 100 kVrms symmetrical
- Switch off time
- < 10 µs
- Test voltage accuracy
- accuracy ± 1 kV over 0 to 100 kV; resolution 0.1 kV
- Voltage slew rate
- 0.5 to 10 kV/s
- Weight
- 39 kg
Data records
- The manufacturer's page for the DTA 100 C was read on the date given in the value. Value: 2026-10-27.
- BAUR lists the DTA 100 C as an oil breakdown voltage tester under its insulating oil testing products. Value: oil dielectric breakdown tester.
- The datasheet states the DTA 100 C carries automatic test sequences for a set of national and international test standards as well as spot tests, and that the user can define additional sequences.
- The datasheet describes breakdown detection performed in the high voltage unit with monitoring of the voltage slew, which BAUR calls Real Breakdown Monitoring.
- The DTA 100 C tests the electrical breakdown strength of insulating liquids in an automatic measurement sequence.
- BAUR states the DTA 100 C is intended for mineral oils, silicone oils and ester liquids.
- The datasheet states the DTA 100 C prints measurement logs on an integrated printer and exports them through a USB data interface to BAUR data management software.
- The datasheet states the DTA 100 C has a built-in sensor for measuring the temperature of the insulating liquid and records the temperature of the oil sample internally.
- The DTA 100 C is a product of BAUR. Value: BAUR.
- The manufacturer gives the model designation as DTA 100 C. Value: DTA 100 C.
- BAUR maintains a product page for the DTA 100 C on its own website, which is the page cited for this entry.
- The manufacturer states the dimensions of the DTA 100 C with the cover closed and with the cover open. Value: 545 x 458 x 380 mm (W x H x D, closed); 545 x 770 x 461 mm (open).
- The manufacturer states a degree of protection for the DTA 100 C. Value: IP32.
- The manufacturer states a mains input voltage range and a maximum power consumption for the DTA 100 C. Value: 90 to 264 V (50/60 Hz), max. 70 VA.
- The manufacturer states a range and a resolution for the internal temperature recording of the oil sample in the DTA 100 C. Value: 0 to 99 °C, resolution 1 °C.
- The manufacturer states an ambient temperature range for operation of the DTA 100 C. Value: -10 °C to +55 °C.
- The manufacturer states an output test voltage range for the DTA 100 C. Value: 0 to 100 kVrms symmetrical.
- The manufacturer states a switch-off time after breakdown for the DTA 100 C. Value: < 10 µs.
- The manufacturer states an accuracy and a resolution for the test voltage measurement of the DTA 100 C. Value: accuracy ± 1 kV over 0 to 100 kV; resolution 0.1 kV.
- The manufacturer states a range of voltage slew rates for the DTA 100 C. Value: 0.5 to 10 kV/s.
- The manufacturer states a weight for the DTA 100 C. Value: 39 kg.
- The datasheet lists ASTM D1816:2012 among the test standards for which the DTA 100 C carries an automatic test sequence. Value: ASTM D1816:2012.
- The datasheet lists ASTM D877/D877M:2019 among the test standards for which the DTA 100 C carries an automatic test sequence. Value: ASTM D877/D877M:2019.
- The datasheet names the European directives under which the DTA 100 C carries CE marking. Value: Low Voltage Directive (2014/35/EU), EMC Directive (2014/30/EU), EN 60068-2-ff Environmental testing.
- The datasheet lists IEC 60156 ED4:2024 among the test standards for which the DTA 100 C carries an automatic test sequence. Value: IEC 60156 ED4:2024.
- The catalog name of the model is written BAUR DTA 100 C. Value: BAUR DTA 100 C.
Sources
- BAUR datasheet, DTA 100 C BAUR oil breakdown voltage tester, data sheet 826-089-9, 10.2025, web page edition, BAUR. Held as: Public page. Publisher page
- BAUR product page, DTA 100 C - Oil breakdown voltage tester, web page edition, BAUR. Held as: Public page. Publisher page
Changelog (53 entries)
| Date | Revision | Change |
|---|---|---|
| 2026-10-27 | created (prod.baur-dta-100-c.checked) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.checked) | |
| 2026-10-27 | created (prod.baur-dta-100-c.class) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.class) | |
| 2026-10-27 | created (prod.baur-dta-100-c.function.automatic-sequences) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.function.automatic-sequences) | |
| 2026-10-27 | created (prod.baur-dta-100-c.function.breakdown-detection) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.function.breakdown-detection) | |
| 2026-10-27 | created (prod.baur-dta-100-c.function.breakdown-voltage) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.function.breakdown-voltage) | |
| 2026-10-27 | created (prod.baur-dta-100-c.function.liquid-types) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.function.liquid-types) | |
| 2026-10-27 | created (prod.baur-dta-100-c.function.logging) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.function.logging) | |
| 2026-10-27 | created (prod.baur-dta-100-c.function.oil-temperature) | |
| 2026-10-27 | revised (prod.baur-dta-100-c.function.oil-temperature) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.function.oil-temperature) | |
| 2026-10-27 | created (prod.baur-dta-100-c.manufacturer) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.manufacturer) | |
| 2026-10-27 | created (prod.baur-dta-100-c.model) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.model) | |
| 2026-10-27 | created (prod.baur-dta-100-c.product-page) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.product-page) | |
| 2026-10-27 | created (prod.baur-dta-100-c.spec.dimensions) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.spec.dimensions) | |
| 2026-10-27 | created (prod.baur-dta-100-c.spec.ingress-rating) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.spec.ingress-rating) | |
| 2026-10-27 | created (prod.baur-dta-100-c.spec.input-voltage) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.spec.input-voltage) | |
| 2026-10-27 | created (prod.baur-dta-100-c.spec.oil-temperature-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.spec.oil-temperature-range) | |
| 2026-10-27 | created (prod.baur-dta-100-c.spec.operating-temperature) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.spec.operating-temperature) | |
| 2026-10-27 | created (prod.baur-dta-100-c.spec.output-voltage) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.spec.output-voltage) | |
| 2026-10-27 | created (prod.baur-dta-100-c.spec.switch-off-time) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.spec.switch-off-time) | |
| 2026-10-27 | created (prod.baur-dta-100-c.spec.test-voltage-accuracy) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.spec.test-voltage-accuracy) | |
| 2026-10-27 | created (prod.baur-dta-100-c.spec.voltage-slew-rate) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.spec.voltage-slew-rate) | |
| 2026-10-27 | created (prod.baur-dta-100-c.spec.weight) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.spec.weight) | |
| 2026-10-27 | created (prod.baur-dta-100-c.standard.astm-d1816) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.standard.astm-d1816) | |
| 2026-10-27 | created (prod.baur-dta-100-c.standard.astm-d877) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.standard.astm-d877) | |
| 2026-10-27 | created (prod.baur-dta-100-c.standard.ce-directives) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.standard.ce-directives) | |
| 2026-10-27 | created (prod.baur-dta-100-c.standard.iec-60156) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.standard.iec-60156) | |
| 2026-10-27 | created (prod.baur-dta-100-c.title) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.baur-dta-100-c.title) |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"BAUR DTA 100 C." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/baur-dta-100-c/.
Test Instrument Reference, BAUR DTA 100 C (Oct. 27, 2026), https://www.testinstrumentreference.com/products/baur-dta-100-c/.
@misc{etr-products-baur-dta-100-c,
title = {BAUR DTA 100 C},
howpublished = {\url{https://www.testinstrumentreference.com/products/baur-dta-100-c/}},
organization = {Test Instrument Reference},
publisher = {Test Instrument Reference},
year = {2026},
note = {last substantive change 2026-10-27}
}{{cite web |title=BAUR DTA 100 C |website=Test Instrument Reference |publisher=Test Instrument Reference |url=https://www.testinstrumentreference.com/products/baur-dta-100-c/ |date=2026-10-27 |access-date=}}