Data record std.iec-61557-16.scope

Verified 2026-10-27 Confidence: High

IEC 61557-16:2014 sets performance requirements for the test and measurement equipment that checks how effective the protective measures of electrical equipment and of medical electrical equipment are, the latter as described in the recurrent-test standard for medical electrical equipment. The publisher states that the standard aims at comparable measuring results, added safety for the person testing and negligible electrical stress on the unit under test.

ProvenanceIEC 61557-16:2014 supports data record std.iec-61557-16.scope, which is cited on the entry Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment.SOURCEIEC 61557-16:2014IEC 61557-16:2014Publisher catalogDATA RECORDstd.iec-61557-16.scopestd.iec-61557-16.scopeVerified 2026-10-27ENTRYElectrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipmentElectrical safety in low..No revisions
Provenance. Where this record comes from and where it is used: the cited source, the record itself and the entry that cites it.
Subject
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment (Standards)
Kind
Standard scope
Source
IEC 61557-16:2014, Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment, IEC. Publisher page

History

Every recorded change to this data record, oldest first.
DateChange
2026-10-27created
2026-10-27revised
2026-10-27review_status unreviewed -> software_reviewed

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Data record std.iec-61557-16.scope." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/data/std.iec-61557-16.scope/.