Data record instr.clamp-meter.one-conductor

Verified 2026-10-27 Confidence: Medium

Only one conductor is placed in the jaw: the supply and return conductors of a circuit carry current in opposite directions whose magnetic fields cancel, so a clamp closed around both conductors reads the difference rather than the load current.

ProvenanceFluke learn index page supports data record instr.clamp-meter.one-conductor, which is cited on the entry Clamp meter.SOURCEFluke learn index pageFluke learn index pageManufacturer pageDATA RECORDinstr.clamp-meter.one-conductorinstr.clamp-meter.one-co..Verified 2026-10-27ENTRYClamp meterClamp meterNo revisions
Provenance. Where this record comes from and where it is used: the cited source, the record itself and the entry that cites it.
Provenance: the chain from source to entry.
StepItemDetail
SourceFluke learn index pageManufacturer page
Data recordinstr.clamp-meter.one-conductorVerified 2026-10-27
EntryClamp meterNo revisions
Subject
Clamp meter (Instrument classes)
Kind
Instrument fact
Source
Fluke learn index page, web page edition, Clamp meter resources and solutions, Fluke. Publisher page

History

Every recorded change to this data record, oldest first.
DateChange
2026-10-27created
2026-10-27review_status unreviewed -> software_reviewed

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Data record instr.clamp-meter.one-conductor." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/data/instr.clamp-meter.one-conductor/.