OMICRON MPD 800

Updated 2026-10-27

OMICRON MPD 800, partial discharge detector
Image: OMICRON, from its product page (www.omicronenergy.com)

Specifications

Figures as the manufacturer states them on its product page or datasheet; each row links its data record.

Bandwidth and sampling
5 kHz to 35 MHz at 125 MS/s
Battery run time
14 h
Multi unit expansion
up to 20 units
Pd dynamic range
140 dB
Synchronization frequency
DC, 0.01 Hz to 10 kHz

Data records

  • The manufacturer's page for the MPD 800 was read on the date given in the value. Value: 2026-10-27. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.checked
  • OMICRON describes the MPD 800 as a partial discharge measurement and analysis system for laboratory, factory and on-site use. Value: partial discharge detector. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.class
  • Each MPD 800 unit provides two partial discharge input channels, and several units can be combined over a fiber optic bus for synchronous measurements on one asset. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.function.multi-channel
  • The MPD 800 applies noise reduction and gating methods to separate partial discharge from disturbances, and correlates events across channels for cable localization and source identification. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.function.noise-reduction
  • The MPD 800 measures partial discharge on transformers, rotating machines, cables, switchgear and instrument transformers, with selectable filters for charge-based and radio influence voltage measurements. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.function.partial-discharge-measurement
  • The MPD 800 records every pulse as raw data and replays it for analysis after the test, including data sets recorded with the MPD 600. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.function.record-replay
  • The MPD 800 includes an automated self-check that verifies the condition of the unit after a flashover or breakdown. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.function.self-check
  • The MPD 800 is a product of OMICRON. Value: OMICRON. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.manufacturer
  • The manufacturer gives the model designation as MPD 800. Value: MPD 800. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.model
  • OMICRON maintains a product page for the MPD 800 on its own website, which is the page cited for this entry. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.product-page
  • The manufacturer states the measurement bandwidth and sampling rate of the MPD 800. Value: 5 kHz to 35 MHz at 125 MS/s. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.spec.bandwidth-and-sampling
  • The manufacturer states the continuous operating time of the MPD 800 on one RBP1 rechargeable battery pack. Value: 14 h. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.spec.battery-run-time
  • The manufacturer states the number of fiber optic bus ports on the MPD 800. Value: 2 x FO ports (for redundancy and multi-unit support). Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.spec.fo-bus
  • The manufacturer states the fiber optic cable length supported by the MPD 800 and by its SiMo variant. Value: MPD 800: 2.5 km; MPD 800 SiMo: approx. 15 km to 40 km. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.spec.fo-cable-length
  • The manufacturer states the input and output channels of one MPD 800 unit. Value: 2 PD channels, 1 OUT port, 2 AC channels, 1 optional trigger. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.spec.input-channels
  • The manufacturer states the number of MPD 800 units that can be combined in one system. Value: up to 20 units. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.spec.multi-unit-expansion
  • The manufacturer states the partial discharge dynamic range of the MPD 800. Value: 140 dB. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.spec.pd-dynamic-range
  • The manufacturer states the maximum partial discharge pulse rate of the MPD 800. Value: up to 4 million per second (2 million per second per FO bus). Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.spec.pd-pulse-rate
  • The manufacturer states the synchronization frequency range of the MPD 800. Value: DC, 0.01 Hz to 10 kHz. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.spec.synchronization-frequency
  • The product page names IEC 60270 in a video on performance checks of the MPD 800; the page gives no edition. Value: IEC 60270. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.standard.iec-60270
  • The catalog name of the model is written OMICRON MPD 800. Value: OMICRON MPD 800. Source: OMICRON product page, web page edition. Verified 2026-10-27. Record prod.omicron-mpd-800.title

Sources

  • OMICRON product page, MPD 800 - Universal partial discharge measurement and analysis system, web page edition, OMICRON electronics. Held as: Public page. Publisher page
Changelog (42 entries)
DateRevisionChange
2026-10-27created (prod.omicron-mpd-800.checked)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.checked)
2026-10-27created (prod.omicron-mpd-800.class)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.class)
2026-10-27created (prod.omicron-mpd-800.function.multi-channel)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.function.multi-channel)
2026-10-27created (prod.omicron-mpd-800.function.noise-reduction)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.function.noise-reduction)
2026-10-27created (prod.omicron-mpd-800.function.partial-discharge-measurement)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.function.partial-discharge-measurement)
2026-10-27created (prod.omicron-mpd-800.function.record-replay)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.function.record-replay)
2026-10-27created (prod.omicron-mpd-800.function.self-check)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.function.self-check)
2026-10-27created (prod.omicron-mpd-800.manufacturer)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.manufacturer)
2026-10-27created (prod.omicron-mpd-800.model)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.model)
2026-10-27created (prod.omicron-mpd-800.product-page)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.product-page)
2026-10-27created (prod.omicron-mpd-800.spec.bandwidth-and-sampling)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.spec.bandwidth-and-sampling)
2026-10-27created (prod.omicron-mpd-800.spec.battery-run-time)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.spec.battery-run-time)
2026-10-27created (prod.omicron-mpd-800.spec.fo-bus)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.spec.fo-bus)
2026-10-27created (prod.omicron-mpd-800.spec.fo-cable-length)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.spec.fo-cable-length)
2026-10-27created (prod.omicron-mpd-800.spec.input-channels)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.spec.input-channels)
2026-10-27created (prod.omicron-mpd-800.spec.multi-unit-expansion)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.spec.multi-unit-expansion)
2026-10-27created (prod.omicron-mpd-800.spec.pd-dynamic-range)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.spec.pd-dynamic-range)
2026-10-27created (prod.omicron-mpd-800.spec.pd-pulse-rate)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.spec.pd-pulse-rate)
2026-10-27created (prod.omicron-mpd-800.spec.synchronization-frequency)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.spec.synchronization-frequency)
2026-10-27created (prod.omicron-mpd-800.standard.iec-60270)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.standard.iec-60270)
2026-10-27created (prod.omicron-mpd-800.title)
2026-10-27review_status unreviewed -> software_reviewed (prod.omicron-mpd-800.title)

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"OMICRON MPD 800." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/omicron-mpd-800/.