Megger TDR2050

Updated 2026-10-27

Megger TDR2050, time domain reflectometer
Image: Megger, from its product page (www.megger.com)

Specifications

Figures as the manufacturer states them on its product page or datasheet; each row links its data record.

Input protection
600 V
Ip rating
IP54
Length measuring range
20 km/65000 ft
Weight
1.7 kg

Data records

  • The manufacturer's page for the TDR2050 was read on the date given in the value. Value: 2026-10-27. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.checked
  • The manufacturer lists the TDR2050 as a two-channel cable fault locator for power applications, a time domain reflectometer. Value: time domain reflectometer. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.class
  • The TDR2050 has an AutoFind function that adjusts range and gain and moves the cursor to detected disturbances, and a FindEnd function that identifies the end of the cable. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.function.autofind-findend
  • The TDR2050 applies distance dependent gain, which increases the gain along the returned trace to compensate for attenuation on longer cables. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.function.distance-dependent-gain
  • The TDR2050 is a time domain reflectometer designed for locating faults in electrical power supply cables. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.function.fault-location
  • The TDR2050 has a built-in input protection filter and is designed for use on energized systems up to its rated voltage. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.function.live-circuit-use
  • The TDR2050 offers a step function in addition to pulse operation, which the manufacturer states maintains a constant injected signal to detect faults close to the test point. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.function.step-tdr
  • The TDR2050 stores traces internally, tags each with a name, compares a stored trace with a live measurement and transfers traces to a PC through the manufacturer's TraceXpert software. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.function.trace-storage
  • The TDR2050 is a product of Megger. Value: Megger. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.manufacturer
  • The manufacturer gives the model designation as TDR2050. Value: TDR2050. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.model
  • Megger maintains a product page for the TDR2050 on its own website, which is the page cited for this entry. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.product-page
  • The manufacturer states a distance accuracy for the TDR2050 at the indicated cursor position, conditional on the velocity factor being correct. Value: ±1% of range ±1 pixel at 0.67 VF. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.spec.accuracy
  • The manufacturer states the battery type, battery life and charge time of the TDR2050. Value: Li-ion rechargeable battery; battery life 12 hours typical; charge time 6 hours at 0 °C to 40 °C. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.spec.battery-life
  • The manufacturer states the display of the TDR2050. Value: 800 x 480 pixel color graphics LCD. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.spec.display
  • The manufacturer states an input protection rating for the TDR2050. Value: 600 V. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.spec.input-protection
  • The manufacturer states an ingress protection rating for the TDR2050. Value: IP54. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.spec.ip-rating
  • The product page states a length measuring range for the TDR2050. Value: 20 km/65000 ft. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.spec.length-measuring-range
  • The manufacturer states the operating temperature range of the TDR2050. Value: -15 °C to +50 °C (5 °F to 122 °F). Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.spec.operating-temperature
  • The manufacturer states the output pulse voltage of the TDR2050 into an open circuit. Value: Up to 20 volts peak to peak into open circuit; pulse widths determined by range and cable. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.spec.output-pulse
  • The manufacturer states the velocity factor range the TDR2050 accepts. Value: 0.2 to 0.99 in steps of 0.01. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.spec.velocity-factor
  • The manufacturer states a weight for the TDR2050. Value: 1.7 kg. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.spec.weight
  • The datasheet lists EN 60950-1 among the standards it names under safety for the TDR2050. Value: EN 60950-1. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.standard.en-60950-1
  • The datasheet lists BS EN 61326-1, light industrial, under electromagnetic compatibility for the TDR2050, with a minimum performance of B for all immunity tests. Value: BS EN 61326-1. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.standard.en-61326-1
  • The datasheet lists EN 62133 among the standards it names under safety for the TDR2050. Value: EN 62133. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.standard.en-62133
  • The datasheet states the TDR2050 is designed to IEC 61010-1 to protect the user when it is connected to live systems. Value: IEC 61010-1. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.standard.iec-61010-1
  • The datasheet lists UN 38.3 among the standards it names under safety for the TDR2050. Value: UN 38.3. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.standard.un-38-3
  • The catalog name of the model is written Megger TDR2050. Value: Megger TDR2050. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-tdr2050.title

Sources

  • Megger datasheet, TDR2000/3, TDR2010 and TDR2050 Advanced Dual Channel TDR datasheet, web page edition, Megger. Held as: Public page. Publisher page
  • Megger product page, Two channel cable locator for power applications TDR2050, web page edition, Megger. Held as: Public page. Publisher page
Changelog (62 entries)
DateRevisionChange
2026-10-27created (prod.megger-tdr2050.checked)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.checked)
2026-10-27created (prod.megger-tdr2050.class)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.class)
2026-10-27created (prod.megger-tdr2050.function.autofind-findend)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.function.autofind-findend)
2026-10-27created (prod.megger-tdr2050.function.distance-dependent-gain)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.function.distance-dependent-gain)
2026-10-27created (prod.megger-tdr2050.function.fault-location)
2026-10-27revised (prod.megger-tdr2050.function.fault-location)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.function.fault-location)
2026-10-27created (prod.megger-tdr2050.function.live-circuit-use)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.function.live-circuit-use)
2026-10-27created (prod.megger-tdr2050.function.step-tdr)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.function.step-tdr)
2026-10-27created (prod.megger-tdr2050.function.trace-storage)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.function.trace-storage)
2026-10-27created (prod.megger-tdr2050.manufacturer)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.manufacturer)
2026-10-27created (prod.megger-tdr2050.model)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.model)
2026-10-27created (prod.megger-tdr2050.product-page)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.product-page)
2026-10-27created (prod.megger-tdr2050.spec.accuracy)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.spec.accuracy)
2026-10-27created (prod.megger-tdr2050.spec.battery-life)
2026-10-27revised (prod.megger-tdr2050.spec.battery-life)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.spec.battery-life)
2026-10-27created (prod.megger-tdr2050.spec.display)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.spec.display)
2026-10-27created (prod.megger-tdr2050.spec.input-protection)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.spec.input-protection)
2026-10-27created (prod.megger-tdr2050.spec.ip-rating)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.spec.ip-rating)
2026-10-27created (prod.megger-tdr2050.spec.length-measuring-range)
2026-10-27revised (prod.megger-tdr2050.spec.length-measuring-range)
2026-10-27revised (prod.megger-tdr2050.spec.length-measuring-range)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.spec.length-measuring-range)
2026-10-27created (prod.megger-tdr2050.spec.operating-temperature)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.spec.operating-temperature)
2026-10-27created (prod.megger-tdr2050.spec.output-pulse)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.spec.output-pulse)
2026-10-27created (prod.megger-tdr2050.spec.velocity-factor)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.spec.velocity-factor)
2026-10-27created (prod.megger-tdr2050.spec.weight)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.spec.weight)
2026-10-27created (prod.megger-tdr2050.standard.en-60950-1)
2026-10-27revised (prod.megger-tdr2050.standard.en-60950-1)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.standard.en-60950-1)
2026-10-27created (prod.megger-tdr2050.standard.en-61326-1)
2026-10-27revised (prod.megger-tdr2050.standard.en-61326-1)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.standard.en-61326-1)
2026-10-27created (prod.megger-tdr2050.standard.en-62133)
2026-10-27revised (prod.megger-tdr2050.standard.en-62133)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.standard.en-62133)
2026-10-27created (prod.megger-tdr2050.standard.iec-61010-1)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.standard.iec-61010-1)
2026-10-27created (prod.megger-tdr2050.standard.un-38-3)
2026-10-27revised (prod.megger-tdr2050.standard.un-38-3)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.standard.un-38-3)
2026-10-27created (prod.megger-tdr2050.title)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-tdr2050.title)

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Megger TDR2050." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/megger-tdr2050/.