Megger PD Scan
Updated 2026-10-27
Specifications
Figures as the manufacturer states them on its product page or datasheet; each row links its data record.
- Acoustic sensor
- -10 to 70 dBµV; resolution 1 dBµV; accuracy ±1 dBµV; transducer center frequency 30, 40 and 80 kHz
- Dimensions
- 220 x 80 x 30 mm (W x H x D)
- Hfct sensor
- -10 to 80 dB; bandwidth 100 kHz to 20 MHz; resolution 1 dB; accuracy ±1 dB / < ±10%; impedance 50 ohm
- Ip rating
- IP 54
- Operating temperature
- -10 to 55 °C
- Weight
- 420 g
Data records
- The manufacturer's page for the PD Scan was read on the date given in the value. Value: 2026-10-27.
- The manufacturer lists the PD Scan as an on-line partial discharge handheld scanner. Value: partial discharge detector.
- The PD Scan has an integrated camera and a QR code scanner.
- The datasheet states a supplied temperature and humidity sensor connects directly to the PD Scan and its readings are stored with the test file.
- The PD Scan accepts external TEV, HFCT, airborne acoustic and contact probe sensors and recognizes which external sensor is connected.
- The PD Scan carries two internal sensors, a TEV sensor and an airborne acoustic sensor.
- The PD Scan detects partial discharge activity in medium voltage and high voltage equipment while the equipment is in service.
- Reports from the PD Scan are produced in the manufacturer's MeggerBook RE software.
- The PD Scan is a product of Megger. Value: Megger.
- The manufacturer gives the model designation as PD Scan. Value: PD Scan.
- Megger maintains a product page for the PD Scan on its own website, which is the page cited for this entry.
- The manufacturer states the measurement range, resolution, accuracy and transducer center frequencies of the acoustic sensor of the PD Scan. Value: -10 to 70 dBµV; resolution 1 dBµV; accuracy ±1 dBµV; transducer center frequency 30, 40 and 80 kHz.
- The manufacturer states the internal battery, operating time and charging time of the PD Scan. Value: Li-Ion 3.6 V / 3.35 Ah; operating time > 8 hours; charging time about 2 hours.
- The manufacturer states the dimensions of the PD Scan main device. Value: 220 x 80 x 30 mm (W x H x D).
- The manufacturer states the display of the PD Scan. Value: 3.5 inch touchscreen, 320 x 240 pixel.
- The manufacturer states the measurement range, bandwidth, resolution, accuracy and impedance of the inductive HFCT sensor input of the PD Scan. Value: -10 to 80 dB; bandwidth 100 kHz to 20 MHz; resolution 1 dB; accuracy ±1 dB / < ±10%; impedance 50 ohm.
- The manufacturer states the interfaces of the PD Scan. Value: Lemo (external sensors); USB type C (charging, headphone, PC); Bluetooth.
- The manufacturer states an ingress protection rating for the PD Scan. Value: IP 54.
- The manufacturer states the operating temperature range of the PD Scan. Value: -10 to 55 °C.
- The manufacturer states the measurement range, bandwidth, resolution and accuracy of the capacitive TEV measurement of the PD Scan. Value: -10 to 80 dBmV; bandwidth 2 to 80 MHz; resolution 1 dBmV; accuracy ±1 dBmV.
- The manufacturer states a weight for the PD Scan main device. Value: 420 g.
- The catalog name of the model is written Megger PD Scan. Value: Megger PD Scan.
Sources
- Megger datasheet, PD Scan handheld scanner for PD surveying in MV and HV plants datasheet, web page edition, Megger. Held as: Public page. Publisher page
- Megger product page, Online PD handheld scanner | PD Scan, web page edition, Megger. Held as: Public page. Publisher page
Changelog (45 entries)
| Date | Revision | Change |
|---|---|---|
| 2026-10-27 | created (prod.megger-pd-scan.checked) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.checked) | |
| 2026-10-27 | created (prod.megger-pd-scan.class) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.class) | |
| 2026-10-27 | created (prod.megger-pd-scan.function.camera-and-qr) | |
| 2026-10-27 | revised (prod.megger-pd-scan.function.camera-and-qr) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.function.camera-and-qr) | |
| 2026-10-27 | created (prod.megger-pd-scan.function.environment-sensor) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.function.environment-sensor) | |
| 2026-10-27 | created (prod.megger-pd-scan.function.external-sensors) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.function.external-sensors) | |
| 2026-10-27 | created (prod.megger-pd-scan.function.internal-sensors) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.function.internal-sensors) | |
| 2026-10-27 | created (prod.megger-pd-scan.function.pd-detection) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.function.pd-detection) | |
| 2026-10-27 | created (prod.megger-pd-scan.function.reporting) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.function.reporting) | |
| 2026-10-27 | created (prod.megger-pd-scan.manufacturer) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.manufacturer) | |
| 2026-10-27 | created (prod.megger-pd-scan.model) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.model) | |
| 2026-10-27 | created (prod.megger-pd-scan.product-page) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.product-page) | |
| 2026-10-27 | created (prod.megger-pd-scan.spec.acoustic-sensor) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.spec.acoustic-sensor) | |
| 2026-10-27 | created (prod.megger-pd-scan.spec.battery) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.spec.battery) | |
| 2026-10-27 | created (prod.megger-pd-scan.spec.dimensions) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.spec.dimensions) | |
| 2026-10-27 | created (prod.megger-pd-scan.spec.display) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.spec.display) | |
| 2026-10-27 | created (prod.megger-pd-scan.spec.hfct-sensor) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.spec.hfct-sensor) | |
| 2026-10-27 | created (prod.megger-pd-scan.spec.interfaces) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.spec.interfaces) | |
| 2026-10-27 | created (prod.megger-pd-scan.spec.ip-rating) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.spec.ip-rating) | |
| 2026-10-27 | created (prod.megger-pd-scan.spec.operating-temperature) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.spec.operating-temperature) | |
| 2026-10-27 | created (prod.megger-pd-scan.spec.tev-measurement) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.spec.tev-measurement) | |
| 2026-10-27 | created (prod.megger-pd-scan.spec.weight) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.spec.weight) | |
| 2026-10-27 | created (prod.megger-pd-scan.title) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.megger-pd-scan.title) |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Megger PD Scan." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/megger-pd-scan/.
Test Instrument Reference, Megger PD Scan (Oct. 27, 2026), https://www.testinstrumentreference.com/products/megger-pd-scan/.
@misc{etr-products-megger-pd-scan,
title = {Megger PD Scan},
howpublished = {\url{https://www.testinstrumentreference.com/products/megger-pd-scan/}},
organization = {Test Instrument Reference},
publisher = {Test Instrument Reference},
year = {2026},
note = {last substantive change 2026-10-27}
}{{cite web |title=Megger PD Scan |website=Test Instrument Reference |publisher=Test Instrument Reference |url=https://www.testinstrumentreference.com/products/megger-pd-scan/ |date=2026-10-27 |access-date=}}