Specifications

Figures as the manufacturer states them on its product page or datasheet; each row links its data record.

Ip rating
IP54
Log capacity
180 measurements
Max output current
220 A
Measurement range
0 to 1000 mΩ, auto range
Operating temperature
-20 °C to +50 °C
Weight
1 kg

Data records

  • The manufacturer's page for the MOM2 was read on the date given in the value. Value: 2026-10-27. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-mom2.checked
  • The manufacturer lists the MOM2 as a handheld micro-ohmmeter. Value: low resistance ohmmeter. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-mom2.class
  • The MOM2 measures the resistance of circuit breaker contacts, busbar joints and other high current links. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-mom2.function.contact-resistance
  • The MOM2 can measure with the test object grounded on both sides throughout the test, the method Megger calls DualGround. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-mom2.function.dual-ground
  • The MOM2 stores test values with a timestamp and transfers them to a computer over Bluetooth. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.function.logging
  • The MOM2 compares a result with a settable pass or fail limit and signals the outcome. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.function.pass-fail
  • The MOM2 generates its test current by discharging an ultracapacitor through the test object, sampling the voltage drop and the current together and averaging the resistance calculated from the samples. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.function.ultracapacitor-source
  • The MOM2 is a product of Megger. Value: Megger. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-mom2.manufacturer
  • The manufacturer gives the model designation as MOM2. Value: MOM2. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-mom2.model
  • Megger maintains a product page for the MOM2 on its own website, which is the page cited for this entry. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-mom2.product-page
  • The manufacturer states the battery cells fitted to the MOM2. Value: five AA (HR6) 2500 mAh NiMH cells. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.spec.battery
  • The manufacturer states the dimensions of the MOM2 excluding its binding posts. Value: 217 x 104 x 72 mm. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.spec.dimensions
  • The manufacturer states the inaccuracy of the MOM2 on its lowest range. Value: ±1 % of reading ±1 digit on 0 to 1999 µΩ. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.spec.inaccuracy
  • The manufacturer states an encapsulation rating for the MOM2. Value: IP54. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.spec.ip-rating
  • The manufacturer states the logger capacity of the MOM2 in running numbers mode. Value: 180 measurements. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.spec.log-capacity
  • The manufacturer states a maximum DC output current for the MOM2. Value: 220 A. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-mom2.spec.max-output-current
  • The manufacturer states the auto ranging resistance measurement range of the MOM2. Value: 0 to 1000 mΩ, auto range. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.spec.measurement-range
  • The manufacturer states the typical number of measurements on fully charged batteries for the MOM2. Value: typ. 2200 at I min = 50 A and 0.1 s; typ. 800 at I min = 100 A and 0.1 s. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.spec.measurements-per-charge
  • The manufacturer states an operating temperature range for the MOM2. Value: -20 °C to +50 °C. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.spec.operating-temperature
  • The manufacturer states a weight for the MOM2 instrument only. Value: 1 kg. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.spec.weight
  • The datasheet lists the European directives on electromagnetic compatibility, low voltage equipment and hazardous substances against which the CE marking of the MOM2 is given. Value: EMC 2014/30/EU, LVD 2014/35/EU, RoHS 2011/65/EU. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.standard.ce-directives
  • The datasheet names IEC 60068-2-27 as the shock test standard for the MOM2. Value: IEC 60068-2-27. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.standard.iec-60068-2-27
  • The datasheet names IEC 60068-2-6 as the vibration test standard for the MOM2. Value: IEC 60068-2-6. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-mom2.standard.iec-60068-2-6
  • Megger marks the product page for the MOM2 as discontinued. Value: discontinued. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-mom2.status
  • The catalog name of the model is written Megger MOM2. Value: Megger MOM2. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-mom2.title

Sources

  • Megger datasheet, MOM2 Handheld micro-ohmmeter 220 A data sheet (MOM2_DS_en_V19a), web page edition, Megger. Held as: Public page. Publisher page
  • Megger product page, MOM2 - Hand-held 200 A micro-ohmmeter, web page edition, Megger. Held as: Public page. Publisher page
Changelog (50 entries)
DateRevisionChange
2026-10-27created (prod.megger-mom2.checked)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.checked)
2026-10-27created (prod.megger-mom2.class)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.class)
2026-10-27created (prod.megger-mom2.function.contact-resistance)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.function.contact-resistance)
2026-10-27created (prod.megger-mom2.function.dual-ground)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.function.dual-ground)
2026-10-27created (prod.megger-mom2.function.logging)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.function.logging)
2026-10-27created (prod.megger-mom2.function.pass-fail)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.function.pass-fail)
2026-10-27created (prod.megger-mom2.function.ultracapacitor-source)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.function.ultracapacitor-source)
2026-10-27created (prod.megger-mom2.manufacturer)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.manufacturer)
2026-10-27created (prod.megger-mom2.model)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.model)
2026-10-27created (prod.megger-mom2.product-page)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.product-page)
2026-10-27created (prod.megger-mom2.spec.battery)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.spec.battery)
2026-10-27created (prod.megger-mom2.spec.dimensions)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.spec.dimensions)
2026-10-27created (prod.megger-mom2.spec.inaccuracy)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.spec.inaccuracy)
2026-10-27created (prod.megger-mom2.spec.ip-rating)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.spec.ip-rating)
2026-10-27created (prod.megger-mom2.spec.log-capacity)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.spec.log-capacity)
2026-10-27created (prod.megger-mom2.spec.max-output-current)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.spec.max-output-current)
2026-10-27created (prod.megger-mom2.spec.measurement-range)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.spec.measurement-range)
2026-10-27created (prod.megger-mom2.spec.measurements-per-charge)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.spec.measurements-per-charge)
2026-10-27created (prod.megger-mom2.spec.operating-temperature)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.spec.operating-temperature)
2026-10-27created (prod.megger-mom2.spec.weight)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.spec.weight)
2026-10-27created (prod.megger-mom2.standard.ce-directives)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.standard.ce-directives)
2026-10-27created (prod.megger-mom2.standard.iec-60068-2-27)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.standard.iec-60068-2-27)
2026-10-27created (prod.megger-mom2.standard.iec-60068-2-6)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.standard.iec-60068-2-6)
2026-10-27created (prod.megger-mom2.status)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.status)
2026-10-27created (prod.megger-mom2.title)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-mom2.title)

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Megger MOM2." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/megger-mom2/.