Figures as the manufacturer states them on its product page or datasheet; each row links its data record.

Max output current
5,000 A

Data records

  • The manufacturer's page for the INGVAR was read on the date given in the value. Value: 2026-10-27. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.checked
  • Megger lists the INGVAR as a primary current injection test system for protective relay equipment and circuit breakers. Value: primary injection test set. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.class
  • The control unit of the INGVAR calculates impedance, power, power factor and phase angle and shows them on the display. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.function.calculated-quantities
  • The datasheet states the INGVAR tests the turns ratio and polarity of current transformers and displays the ratio directly as a nominal value. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.function.ct-ratio-polarity
  • A current reduction function lets the operator preset the test current of the INGVAR at a reduced level before injection, which the manufacturer states prevents heating of the test object. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.function.low-current-preset
  • The INGVAR injects a high AC current for primary injection testing of low voltage circuit breakers and protective relay equipment and stops timing when the breaker interrupts the current. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.function.primary-injection
  • The datasheet states the INGVAR can be set to test circuit breakers with reclosing relays and sectionalizers and to perform heat runs. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.function.reclosers-and-heat-runs
  • An INGVAR system consists of a control unit and a current unit whose outputs can be connected in parallel or in series. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.function.two-unit-system
  • The INGVAR is a product of Megger. Value: Megger. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.manufacturer
  • The manufacturer gives the model designation as INGVAR. Value: INGVAR. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.model
  • Megger maintains a product page for the INGVAR on its own website, which is the page cited for this entry. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.product-page
  • The datasheet states the main ammeter ranges and inaccuracy of the INGVAR. Value: serial low 0 to 2.15 kA; serial high 0 to 3.30 kA; parallel low 0 to 4.00 kA; parallel high 0 to 6.50 kA; inaccuracy 1 % of range ±1 digit. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.spec.ammeter-1-ranges
  • The datasheet states the dimensions of the control unit and of the current unit of the INGVAR. Value: control unit 546 x 347 x 247 mm (21.5 x 13.7 x 9.7 in); current unit 410 x 340 x 205 mm (16.1 x 13.4 x 8 in). Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.spec.dimensions
  • The datasheet states the mains voltage range and the mains inlet rating of the INGVAR. Value: 100 to 240 V AC, 50/60 Hz; IEC 60309-1, -2 inlet, 16 A. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.spec.mains-voltage
  • The product page states the maximum AC output current of the INGVAR in parallel mode with its generation time and load voltage. Value: 5,000 A. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.spec.max-output-current
  • The datasheet states the measurement category and rated transient overvoltage of the INGVAR. Value: CAT I, rated transient overvoltage 2200 V. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.spec.measurement-category
  • The datasheet states the operating temperature range of the INGVAR. Value: 0 °C to +50 °C (+32 °F to +122 °F). Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.spec.operating-temperature
  • The datasheet states the output ratings of the INGVAR with the outputs in parallel on the higher mains voltage. Value: parallel, 240 V mains: 700 A continuous (2.6 V load voltage); 1000 A for 30 min; 2000 A for 3 min; 3000 A for 1 min; 5000 A for 2 s. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.spec.outputs-parallel
  • The datasheet states the output ratings of the INGVAR with the outputs in series on the higher mains voltage. Value: series, 240 V mains: 6 V no-load voltage; 350 A continuous; 500 A for 20 min; 1500 A for 2 min. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.spec.outputs-series
  • The datasheet states the weight of the control unit and of the current unit of the INGVAR. Value: control unit 20 kg (44 lbs); current unit 21 kg (46.3 lbs). Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.spec.weight
  • The datasheet gives the mains inlet of the INGVAR as a connector to IEC 60309-1 and IEC 60309-2 and gives no edition. Value: IEC 60309-1, -2. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.standard.iec-60309
  • The catalog name of the model is written Megger INGVAR. Value: Megger INGVAR. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-ingvar.title

Sources

  • Megger datasheet, INGVAR Primary Current Injection Test System data sheet, web page edition, Megger. Held as: Public page. Publisher page
  • Megger product page, INGVAR - Primary Current Injection Test System, web page edition, Megger. Held as: Public page. Publisher page
Changelog (45 entries)
DateRevisionChange
2026-10-27created (prod.megger-ingvar.checked)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.checked)
2026-10-27created (prod.megger-ingvar.class)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.class)
2026-10-27created (prod.megger-ingvar.function.calculated-quantities)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.function.calculated-quantities)
2026-10-27created (prod.megger-ingvar.function.ct-ratio-polarity)
2026-10-27revised (prod.megger-ingvar.function.ct-ratio-polarity)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.function.ct-ratio-polarity)
2026-10-27created (prod.megger-ingvar.function.low-current-preset)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.function.low-current-preset)
2026-10-27created (prod.megger-ingvar.function.primary-injection)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.function.primary-injection)
2026-10-27created (prod.megger-ingvar.function.reclosers-and-heat-runs)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.function.reclosers-and-heat-runs)
2026-10-27created (prod.megger-ingvar.function.two-unit-system)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.function.two-unit-system)
2026-10-27created (prod.megger-ingvar.manufacturer)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.manufacturer)
2026-10-27created (prod.megger-ingvar.model)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.model)
2026-10-27created (prod.megger-ingvar.product-page)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.product-page)
2026-10-27created (prod.megger-ingvar.spec.ammeter-1-ranges)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.spec.ammeter-1-ranges)
2026-10-27created (prod.megger-ingvar.spec.dimensions)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.spec.dimensions)
2026-10-27created (prod.megger-ingvar.spec.mains-voltage)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.spec.mains-voltage)
2026-10-27created (prod.megger-ingvar.spec.max-output-current)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.spec.max-output-current)
2026-10-27created (prod.megger-ingvar.spec.measurement-category)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.spec.measurement-category)
2026-10-27created (prod.megger-ingvar.spec.operating-temperature)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.spec.operating-temperature)
2026-10-27created (prod.megger-ingvar.spec.outputs-parallel)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.spec.outputs-parallel)
2026-10-27created (prod.megger-ingvar.spec.outputs-series)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.spec.outputs-series)
2026-10-27created (prod.megger-ingvar.spec.weight)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.spec.weight)
2026-10-27created (prod.megger-ingvar.standard.iec-60309)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.standard.iec-60309)
2026-10-27created (prod.megger-ingvar.title)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-ingvar.title)

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Megger INGVAR." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/megger-ingvar/.