Megger DET4TC2

Updated 2026-10-27

Megger DET4TC2, ground resistance tester
Image: Megger, from its product page (www.megger.com)

Specifications

Figures as the manufacturer states them on its product page or datasheet; each row links its data record.

Ingress protection
IP54
Weight
1 kg

Data records

  • The manufacturer's page for the DET4TC2 was read on the date given in the value. Value: 2026-10-27. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.checked
  • Megger lists the DET4TC2 as a dry-cell battery-powered four-terminal earth/ground resistance tester in its DET4 series. Value: ground resistance tester. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.class
  • The datasheet states that with the optional MCC CLAMP the DET4TC2 performs attached rod technique measurements, which test an electrode without disconnecting it, and measures leakage current. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.function.attached-rod-technique
  • The DET4TC2 measures earth electrode resistance by two-, three- and four-pole test methods. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.function.earth-resistance
  • The DET4TC2 measures earth noise voltage and leakage current. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.function.noise-voltage-and-current
  • The operator selects one of four test frequencies on the DET4TC2 to reduce the effect of interference. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.function.selectable-test-frequency
  • The DET4TC2 measures soil resistivity by the four-terminal method. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.function.soil-resistivity
  • The datasheet states that with the MCC CLAMP and MVC CLAMP together the DET4TC2 makes stakeless measurements where driving stakes is not practical. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.function.stakeless-measurement
  • The DET4TC2 is a product of Megger. Value: Megger. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.manufacturer
  • The manufacturer gives the model designation as DET4TC2. Value: DET4TC2. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.model
  • Megger maintains a product page for the DET4 series, which describes the DET4TC2 as one of its four models, on its own website; that page is the one cited for this entry. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.product-page
  • The datasheet states the battery type of the DET4TC2. Value: 8 AA (LR6) cells. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.spec.battery
  • The datasheet states the dimensions of the DET4TC2. Value: 203 mm x 148 mm x 78 mm (8 in x 5.8 in x 3 in). Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.spec.dimensions
  • The datasheet states the ingress protection rating of the DET4TC2. Value: IP54. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.spec.ingress-protection
  • The datasheet states the measurement category rating of the DET4TC2 between terminal pairs, dependent on a lead set of at least that rating. Value: 100 V CAT IV between terminal pairs. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.spec.measurement-category
  • The datasheet states the operating temperature range of the DET4TC2. Value: -15 °C to +55 °C / 5 °F to 131 °F. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.spec.operating-temperature
  • The datasheet states the selectable instrument output voltage and the test currents of the DET4TC2. Value: ±25 V or ±50 V; current 4.5 mA or 0.45 mA or 0.045 mA. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.spec.output-voltage
  • The datasheet states the resistance accuracy of the DET4TC2 for each test method. Value: 2P, 3P, 4P: 2 % ±3 digits; ART: 5 % ±3 digits; stakeless: 7 % ±3 digits. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.spec.resistance-accuracy
  • The datasheet states the resistance measuring ranges of the DET4TC2 for each test method. Value: 2, 3, 4 pole: 0.01 Ω to 20 kΩ; ART: 0.01 Ω to 200 kΩ; stakeless: 0.01 Ω to 200 Ω. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.spec.resistance-range
  • The datasheet states the four selectable test frequencies of the DET4TC2. Value: 94 Hz, 105 Hz, 111 Hz and 128 Hz. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.spec.test-frequencies
  • The datasheet states the weight of the DET4TC2. Value: 1 kg. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.spec.weight
  • The datasheet names the general requirements and the resistance to earth parts of EN 61557 for the DET4TC2 and states the selectable output voltage is provided for IEC 61557-5, with no edition given. Value: EN 61557-1; EN 61557-5; IEC 61557-5. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.standard.en-61557
  • The datasheet states the DET4TC2 is designed to the requirements of IEC 61010-1 for its measurement category rating between terminal pairs and gives no edition. Value: IEC 61010-1. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.standard.iec-61010-1
  • The datasheet names IEC 61326-1 for the electromagnetic compatibility of the DET4TC2 and gives no edition. Value: IEC 61326-1. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.standard.iec-61326-1
  • The datasheet states the DET4TC2 is designed to the requirements of KEMA K85B. Value: KEMA K85B. Source: Megger datasheet, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.standard.kema-k85b
  • The catalog name of the model is written Megger DET4TC2. Value: Megger DET4TC2. Source: Megger product page, web page edition. Verified 2026-10-27. Record prod.megger-det4tc2.title

Sources

  • Megger datasheet, DET4TC2 and DET4TCR2 Digital Ground Testers data sheet (DET4TC2_DET4TCR2_DS_en_V14), web page edition, Megger. Held as: Public page. Publisher page
  • Megger product page, DET4 series four-terminal earth/ground resistance testers, web page edition, Megger. Held as: Public page. Publisher page
Changelog (56 entries)
DateRevisionChange
2026-10-27created (prod.megger-det4tc2.checked)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.checked)
2026-10-27created (prod.megger-det4tc2.class)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.class)
2026-10-27created (prod.megger-det4tc2.function.attached-rod-technique)
2026-10-27revised (prod.megger-det4tc2.function.attached-rod-technique)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.function.attached-rod-technique)
2026-10-27created (prod.megger-det4tc2.function.earth-resistance)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.function.earth-resistance)
2026-10-27created (prod.megger-det4tc2.function.noise-voltage-and-current)
2026-10-27revised (prod.megger-det4tc2.function.noise-voltage-and-current)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.function.noise-voltage-and-current)
2026-10-27created (prod.megger-det4tc2.function.selectable-test-frequency)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.function.selectable-test-frequency)
2026-10-27created (prod.megger-det4tc2.function.soil-resistivity)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.function.soil-resistivity)
2026-10-27created (prod.megger-det4tc2.function.stakeless-measurement)
2026-10-27revised (prod.megger-det4tc2.function.stakeless-measurement)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.function.stakeless-measurement)
2026-10-27created (prod.megger-det4tc2.manufacturer)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.manufacturer)
2026-10-27created (prod.megger-det4tc2.model)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.model)
2026-10-27created (prod.megger-det4tc2.product-page)
2026-10-27revised (prod.megger-det4tc2.product-page)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.product-page)
2026-10-27created (prod.megger-det4tc2.spec.battery)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.spec.battery)
2026-10-27created (prod.megger-det4tc2.spec.dimensions)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.spec.dimensions)
2026-10-27created (prod.megger-det4tc2.spec.ingress-protection)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.spec.ingress-protection)
2026-10-27created (prod.megger-det4tc2.spec.measurement-category)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.spec.measurement-category)
2026-10-27created (prod.megger-det4tc2.spec.operating-temperature)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.spec.operating-temperature)
2026-10-27created (prod.megger-det4tc2.spec.output-voltage)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.spec.output-voltage)
2026-10-27created (prod.megger-det4tc2.spec.resistance-accuracy)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.spec.resistance-accuracy)
2026-10-27created (prod.megger-det4tc2.spec.resistance-range)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.spec.resistance-range)
2026-10-27created (prod.megger-det4tc2.spec.test-frequencies)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.spec.test-frequencies)
2026-10-27created (prod.megger-det4tc2.spec.weight)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.spec.weight)
2026-10-27created (prod.megger-det4tc2.standard.en-61557)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.standard.en-61557)
2026-10-27created (prod.megger-det4tc2.standard.iec-61010-1)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.standard.iec-61010-1)
2026-10-27created (prod.megger-det4tc2.standard.iec-61326-1)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.standard.iec-61326-1)
2026-10-27created (prod.megger-det4tc2.standard.kema-k85b)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.standard.kema-k85b)
2026-10-27created (prod.megger-det4tc2.title)
2026-10-27review_status unreviewed -> software_reviewed (prod.megger-det4tc2.title)

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Megger DET4TC2." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/megger-det4tc2/.