Hioki PQ3198
Updated 2026-10-27
Specifications
Figures as the manufacturer states them on its product page or datasheet; each row links its data record.
- Current range
- 500.00 mA to 5.0000 kA AC
- Dimensions and mass
- 300 mm W x 211 mm H x 68 mm D, 2.6 kg
- Display
- 6.5 in
- Measurement line types
- Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire or three-phase 4-wire plus one extra input channel for voltage, current and power (AC or DC)
- Power range
- 300.00 W to 3.0000 MW
- Supraharmonic range
- 2 kHz to 80 kHz
Data records
- The manufacturer's page for the PQ3198 was read on the date given in the value. Value: 2026-10-27.
- Hioki lists the PQ3198 as a three-phase power quality analyzer for monitoring and recording power supply anomalies. Value: power quality analyzer.
- The PQ3198 measures flicker and mains signaling voltage.
- The PQ3198 measures harmonics, interharmonics, total harmonic distortion, the K factor and high-order supraharmonic components of voltage and current.
- The PQ3198 logs power parameters continuously while capturing the waveforms of power quality events such as transients, swells, dips, interruptions, inrush current, frequency fluctuation and unbalance.
- The PQ3198 is bundled with the PQ ONE software, which produces reports, statistics, ITIC curves and CSV or PQDIF files from the recorded data.
- The PQ3198 corrects its internal clock to UTC with the optional PW9005 GPS box so that recordings from several instruments can be aligned.
- The PQ3198 measures power and efficiency on two separate circuits at once because its fourth voltage channel is isolated from the first three.
- The PQ3198 is a product of Hioki. Value: Hioki.
- The manufacturer gives the model designation as PQ3198. Value: PQ3198.
- Hioki maintains a product page for the PQ3198 on its own website, which is the page cited for this entry.
- The manufacturer states the basic accuracy of the PQ3198 for voltage, current and active power. Value: voltage ±0.1 % of nominal voltage; current ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy; active power ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy.
- The manufacturer states the current measurement range of the PQ3198, which depends on the current sensor in use. Value: 500.00 mA to 5.0000 kA AC.
- The manufacturer states the dimensions and mass of the PQ3198 including the Z1003 battery pack. Value: 300 mm W x 211 mm H x 68 mm D, 2.6 kg.
- The manufacturer states the display size and resolution of the PQ3198. Value: 6.5 in.
- The manufacturer states the wiring configurations the PQ3198 measures. Value: Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire or three-phase 4-wire plus one extra input channel for voltage, current and power (AC or DC).
- The manufacturer states the power measurement range of the PQ3198. Value: 300.00 W to 3.0000 MW.
- The manufacturer states the AC adapter rating and battery run time of the PQ3198. Value: AC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A); battery pack Z1003 continuous use 180 minutes, charging time max. 5 h 30 min.
- The manufacturer states the maximum recording duration and event count of the PQ3198. Value: repeated on: 1 year, up to 9999 events per day over 366 days; repeated off: 35 days, up to 9999 events.
- The manufacturer states the frequency range of the high-order harmonic component measurement of the PQ3198. Value: 2 kHz to 80 kHz.
- The manufacturer states the voltage measurement range and the transient measurement range of the PQ3198. Value: voltage measurement 600.00 V rms; transient measurement 6.0000 kV peak.
- The product page names EN 50160 as the standard the PQ ONE software judges recorded voltage data against; the page gives no edition. Value: EN 50160.
- The product page names IEC 61000-4-15 as the standard the instantaneous flicker value of the PQ3198 is calculated to; the page gives no edition. Value: IEC 61000-4-15.
- Hioki states that the PQ3198 performs power quality measurement to IEC 61000-4-30 Edition 3 Class A and publishes a certificate of conformity for that edition on the product page. Value: IEC 61000-4-30 Edition 3.
- The product page names IEEE 519 as the standard whose harmonic measurement reports the PQ3198 software produces; the page gives no edition. Value: IEEE 519.
- The catalog name of the model is written Hioki PQ3198. Value: Hioki PQ3198.
Sources
- Hioki product page, PQ3198 Power Quality Analyzer - IEC 61000-4-30 Class A | HIOKI, web page edition, Hioki. Held as: Public page. Publisher page
Changelog (52 entries)
| Date | Revision | Change |
|---|---|---|
| 2026-10-27 | created (prod.hioki-pq3198.checked) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.checked) | |
| 2026-10-27 | created (prod.hioki-pq3198.class) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.class) | |
| 2026-10-27 | created (prod.hioki-pq3198.function.flicker) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.function.flicker) | |
| 2026-10-27 | created (prod.hioki-pq3198.function.harmonics) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.function.harmonics) | |
| 2026-10-27 | created (prod.hioki-pq3198.function.power-quality-recording) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.function.power-quality-recording) | |
| 2026-10-27 | created (prod.hioki-pq3198.function.reporting-software) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.function.reporting-software) | |
| 2026-10-27 | created (prod.hioki-pq3198.function.time-synchronization) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.function.time-synchronization) | |
| 2026-10-27 | created (prod.hioki-pq3198.function.two-circuit-measurement) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.function.two-circuit-measurement) | |
| 2026-10-27 | created (prod.hioki-pq3198.manufacturer) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.manufacturer) | |
| 2026-10-27 | created (prod.hioki-pq3198.model) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.model) | |
| 2026-10-27 | created (prod.hioki-pq3198.product-page) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.product-page) | |
| 2026-10-27 | created (prod.hioki-pq3198.spec.basic-accuracy) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.spec.basic-accuracy) | |
| 2026-10-27 | created (prod.hioki-pq3198.spec.current-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.spec.current-range) | |
| 2026-10-27 | created (prod.hioki-pq3198.spec.dimensions-and-mass) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.spec.dimensions-and-mass) | |
| 2026-10-27 | created (prod.hioki-pq3198.spec.display) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.spec.display) | |
| 2026-10-27 | created (prod.hioki-pq3198.spec.measurement-line-types) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.spec.measurement-line-types) | |
| 2026-10-27 | created (prod.hioki-pq3198.spec.power-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.spec.power-range) | |
| 2026-10-27 | created (prod.hioki-pq3198.spec.power-supply) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.spec.power-supply) | |
| 2026-10-27 | created (prod.hioki-pq3198.spec.recording) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.spec.recording) | |
| 2026-10-27 | created (prod.hioki-pq3198.spec.supraharmonic-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.spec.supraharmonic-range) | |
| 2026-10-27 | created (prod.hioki-pq3198.spec.voltage-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.spec.voltage-range) | |
| 2026-10-27 | created (prod.hioki-pq3198.standard.en-50160) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.standard.en-50160) | |
| 2026-10-27 | created (prod.hioki-pq3198.standard.iec-61000-4-15) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.standard.iec-61000-4-15) | |
| 2026-10-27 | created (prod.hioki-pq3198.standard.iec-61000-4-30) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.standard.iec-61000-4-30) | |
| 2026-10-27 | created (prod.hioki-pq3198.standard.ieee-519) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.standard.ieee-519) | |
| 2026-10-27 | created (prod.hioki-pq3198.title) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-pq3198.title) |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Hioki PQ3198." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/hioki-pq3198/.
Test Instrument Reference, Hioki PQ3198 (Oct. 27, 2026), https://www.testinstrumentreference.com/products/hioki-pq3198/.
@misc{etr-products-hioki-pq3198,
title = {Hioki PQ3198},
howpublished = {\url{https://www.testinstrumentreference.com/products/hioki-pq3198/}},
organization = {Test Instrument Reference},
publisher = {Test Instrument Reference},
year = {2026},
note = {last substantive change 2026-10-27}
}{{cite web |title=Hioki PQ3198 |website=Test Instrument Reference |publisher=Test Instrument Reference |url=https://www.testinstrumentreference.com/products/hioki-pq3198/ |date=2026-10-27 |access-date=}}