Hioki IR4056
Updated 2026-10-27
Specifications
Figures as the manufacturer states them on its product page or datasheet; each row links its data record.
- Ac voltage range
- 420 V (0.1 V resolution) / 600 V (1 V resolution), 2 ranges, 50/60 Hz, ±2.3 % rdg. ±8 dgt.
- Dc voltage range
- 4.2 V (0.001 V resolution) to 600 V (1 V resolution), 4 ranges, ±1.3 % rdg. ±4 dgt.
- Dimensions and mass
- 159 mm W x 177 mm H x 53 mm D, 600 g
- Insulation accuracy
- ±2 % rdg. ±2 dgt.
- Low resistance range
- 10 Ω (0.01 Ω resolution) to 1000 Ω (1 Ω resolution), 3 ranges, testing current 200 mA or more at 6 Ω or less
- Maximum indicated resistance
- 100 MΩ at 50 V to 4000 MΩ at 1000 V
- Measurement category
- CAT III 600 V
- Power supply
- LR6 (AA) alkaline batteries x4, continuous use 20 hours (comparator off, backlight off, 500 V range, no load)
- Rated output voltages
- 50 V, 125 V, 250 V, 500 V, 1000 V DC
- Response time
- 0.8 s
Data records
- The manufacturer's page for the IR4056 was read on the date given in the value. Value: 2026-10-27.
- Hioki lists the IR4056 as a digital insulation tester with five test voltage ranges, sold under the order codes IR4056-20 and IR4056-21. Value: insulation resistance tester.
- The IR4056 compares measured values with preset reference values and signals a pass or fail result by a beeper, the display light and a lamp on the remote-switch test lead when that lead is used.
- The IR4056 checks the continuity of ground wiring with a low resistance measurement range.
- The IR4056 measures insulation resistance at one of five selectable DC test voltages and shows the reading on a digital display with a bar graph.
- The IR4056 has a live circuit indicator, an automatic electric discharge function and an automatic power-save function.
- The IR4056 has a built-in AC and DC voltmeter with automatic detection of the voltage type.
- The IR4056 is a product of Hioki. Value: Hioki.
- The manufacturer gives the model designation as IR4056. Value: IR4056.
- Hioki maintains a product page for the IR4056 on its own website, which is the page cited for this entry.
- The manufacturer states the AC voltage measurement ranges and accuracy of the IR4056. Value: 420 V (0.1 V resolution) / 600 V (1 V resolution), 2 ranges, 50/60 Hz, ±2.3 % rdg. ±8 dgt..
- The manufacturer states the DC voltage measurement ranges and accuracy of the IR4056. Value: 4.2 V (0.001 V resolution) to 600 V (1 V resolution), 4 ranges, ±1.3 % rdg. ±4 dgt..
- The manufacturer states the dimensions and mass of the IR4056 including batteries and excluding test leads. Value: 159 mm W x 177 mm H x 53 mm D, 600 g.
- The manufacturer states the accuracy of the IR4056 in the first effective measuring range of each test voltage. Value: ±2 % rdg. ±2 dgt..
- The manufacturer states the low resistance ranges, resolution and test current of the continuity function of the IR4056. Value: 10 Ω (0.01 Ω resolution) to 1000 Ω (1 Ω resolution), 3 ranges, testing current 200 mA or more at 6 Ω or less.
- The manufacturer states the effective maximum indicated insulation resistance of the IR4056 at its lowest and highest test voltages. Value: 100 MΩ at 50 V to 4000 MΩ at 1000 V.
- The manufacturer states the measurement category rating of the IR4056. Value: CAT III 600 V.
- The manufacturer states the battery type and continuous operating time of the IR4056. Value: LR6 (AA) alkaline batteries x4, continuous use 20 hours (comparator off, backlight off, 500 V range, no load).
- The manufacturer states the five rated DC output voltages of the IR4056. Value: 50 V, 125 V, 250 V, 500 V, 1000 V DC.
- The manufacturer states the approximate response time of the IR4056 for a pass or fail decision, based on in-house testing. Value: 0.8 s.
- The product page names IEC 60364 as the standard that defines the resistance measurement of safety conductors in building electrical equipment that the continuity function of the IR4056 performs; the page gives no edition. Value: IEC 60364.
- The catalog name of the model is written Hioki IR4056. Value: Hioki IR4056.
Sources
- Hioki product page, INSULATION TESTER IR4056 | HIOKI, web page edition, Hioki. Held as: Public page. Publisher page
Changelog (45 entries)
| Date | Revision | Change |
|---|---|---|
| 2026-10-27 | created (prod.hioki-ir4056.checked) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.checked) | |
| 2026-10-27 | created (prod.hioki-ir4056.class) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.class) | |
| 2026-10-27 | created (prod.hioki-ir4056.function.comparator) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.function.comparator) | |
| 2026-10-27 | created (prod.hioki-ir4056.function.continuity-check) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.function.continuity-check) | |
| 2026-10-27 | created (prod.hioki-ir4056.function.insulation-resistance) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.function.insulation-resistance) | |
| 2026-10-27 | created (prod.hioki-ir4056.function.safety-functions) | |
| 2026-10-27 | revised (prod.hioki-ir4056.function.safety-functions) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.function.safety-functions) | |
| 2026-10-27 | created (prod.hioki-ir4056.function.voltage-measurement) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.function.voltage-measurement) | |
| 2026-10-27 | created (prod.hioki-ir4056.manufacturer) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.manufacturer) | |
| 2026-10-27 | created (prod.hioki-ir4056.model) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.model) | |
| 2026-10-27 | created (prod.hioki-ir4056.product-page) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.product-page) | |
| 2026-10-27 | created (prod.hioki-ir4056.spec.ac-voltage-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.spec.ac-voltage-range) | |
| 2026-10-27 | created (prod.hioki-ir4056.spec.dc-voltage-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.spec.dc-voltage-range) | |
| 2026-10-27 | created (prod.hioki-ir4056.spec.dimensions-and-mass) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.spec.dimensions-and-mass) | |
| 2026-10-27 | created (prod.hioki-ir4056.spec.insulation-accuracy) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.spec.insulation-accuracy) | |
| 2026-10-27 | created (prod.hioki-ir4056.spec.low-resistance-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.spec.low-resistance-range) | |
| 2026-10-27 | created (prod.hioki-ir4056.spec.maximum-indicated-resistance) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.spec.maximum-indicated-resistance) | |
| 2026-10-27 | created (prod.hioki-ir4056.spec.measurement-category) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.spec.measurement-category) | |
| 2026-10-27 | created (prod.hioki-ir4056.spec.power-supply) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.spec.power-supply) | |
| 2026-10-27 | created (prod.hioki-ir4056.spec.rated-output-voltages) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.spec.rated-output-voltages) | |
| 2026-10-27 | created (prod.hioki-ir4056.spec.response-time) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.spec.response-time) | |
| 2026-10-27 | created (prod.hioki-ir4056.standard.iec-60364) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.standard.iec-60364) | |
| 2026-10-27 | created (prod.hioki-ir4056.title) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.hioki-ir4056.title) |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Hioki IR4056." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/hioki-ir4056/.
Test Instrument Reference, Hioki IR4056 (Oct. 27, 2026), https://www.testinstrumentreference.com/products/hioki-ir4056/.
@misc{etr-products-hioki-ir4056,
title = {Hioki IR4056},
howpublished = {\url{https://www.testinstrumentreference.com/products/hioki-ir4056/}},
organization = {Test Instrument Reference},
publisher = {Test Instrument Reference},
year = {2026},
note = {last substantive change 2026-10-27}
}{{cite web |title=Hioki IR4056 |website=Test Instrument Reference |publisher=Test Instrument Reference |url=https://www.testinstrumentreference.com/products/hioki-ir4056/ |date=2026-10-27 |access-date=}}