Fluke 1555 FC
Updated 2026-10-27
Specifications
Figures as the manufacturer states them on its product page or datasheet; each row links its data record.
- Capacitance range
- 0.01 µF to 15.00 µF; accuracy ±(15% of reading + 0.03 µF)
- Leakage current range
- 1 nA to 2 mA; accuracy ±(5% + 2 nA)
- Live circuit warning
- 30 V to 660 V AC/DC, 50/60 Hz
- Maximum resistance
- 2 TΩ
- Measurement category
- CAT III 1000 V, CAT IV 600 V
- Test voltage accuracy
- -0%, +10% at 1 mA load current
- Test voltage range
- 250 V to 10000 V DC; 250 V to 1000 V in 50 V steps, 100 V steps above 1000 V
- Weight
- 3.7 kg
Data records
- The manufacturer's page for the 1555 FC was read on the date given in the value. Value: 2026-10-27.
- The manufacturer lists the 1555 FC as an insulation resistance tester for high voltage equipment including switchgear, motors, generators and cables. Value: insulation resistance tester.
- The 1555 FC has a guard system that the manufacturer states eliminates the effect of surface leakage current on high resistance measurements.
- The 1555 FC measures insulation resistance at DC test voltages selectable in steps across its range.
- The 1555 FC measures the leakage current and the capacitance of the item under test.
- The 1555 FC calculates the dielectric absorption ratio and the polarization index automatically, with no additional setup.
- The 1555 FC has a ramp function for breakdown testing and a timer for timed tests.
- With the ir3000 FC connector, the 1555 FC pairs with the manufacturer's Fluke Connect application so the operator can configure, start and stop tests from a mobile device at a distance from the equipment under test.
- The 1555 FC is a product of Fluke. Value: Fluke.
- The manufacturer gives the model designation as 1555 FC. Value: 1555 FC.
- Fluke maintains a product page for the 1555 FC on its own website, which is the page cited for this entry.
- The manufacturer states the insulation resistance accuracy of the 1555 FC at its highest test voltage in two bands of resistance. Value: at 10000 V: ±5% of reading from 10 MΩ to 200 GΩ; ±20% of reading from 200 GΩ to 2 TΩ.
- The manufacturer states the battery type and the number of tests between charges for the 1555 FC. Value: 12 V lead-acid rechargeable battery (Yuasa NP2.8-12); over 750 tests between charges.
- The manufacturer states a capacitance measurement range and accuracy for the 1555 FC. Value: 0.01 µF to 15.00 µF; accuracy ±(15% of reading + 0.03 µF).
- The manufacturer states a leakage current range and accuracy for the 1555 FC. Value: 1 nA to 2 mA; accuracy ±(5% + 2 nA).
- The manufacturer states the voltage range over which the 1555 FC warns that a live circuit is connected. Value: 30 V to 660 V AC/DC, 50/60 Hz.
- The manufacturer states a maximum measurable insulation resistance for the 1555 FC. Value: 2 TΩ.
- The manufacturer states a measurement category rating for the 1555 FC. Value: CAT III 1000 V, CAT IV 600 V.
- The manufacturer states a test voltage accuracy for the 1555 FC at a stated load current. Value: -0%, +10% at 1 mA load current.
- The manufacturer states the DC test voltage range of the 1555 FC and the steps in which it is selected. Value: 250 V to 10000 V DC; 250 V to 1000 V in 50 V steps, 100 V steps above 1000 V.
- The manufacturer states a weight for the 1555 FC. Value: 3.7 kg.
- The product page lists EN 61326 under electromagnetic compatibility for the 1555 FC. Value: EN 61326.
- The product page names IEC 61010-1 as the safety standard the 1555 FC is designed to. Value: IEC 61010-1.
- The product page names IEC 61010-2-030 as the standard under which the measurement category of the 1555 FC is rated. Value: IEC 61010-2-030.
- The product page lists IEC 61557-1 and IEC 61557-2 under safety for the 1555 FC. Value: IEC 61557-1; IEC 61557-2.
- The product page states the 1555 FC can conduct the entire range of test voltages specified in IEEE 43-2000. Value: IEEE 43-2000.
- The catalog name of the model is written Fluke 1555 FC. Value: Fluke 1555 FC.
Sources
- Fluke product page, Fluke 1555 FC 10 kV Insulation Tester, web page edition, Fluke. Held as: Public page. Publisher page
Changelog (60 entries)
| Date | Revision | Change |
|---|---|---|
| 2026-10-27 | created (prod.fluke-1555-fc.checked) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.checked) | |
| 2026-10-27 | created (prod.fluke-1555-fc.class) | |
| 2026-10-27 | revised (prod.fluke-1555-fc.class) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.class) | |
| 2026-10-27 | created (prod.fluke-1555-fc.function.guard-terminal) | |
| 2026-10-27 | revised (prod.fluke-1555-fc.function.guard-terminal) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.function.guard-terminal) | |
| 2026-10-27 | created (prod.fluke-1555-fc.function.insulation-resistance) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.function.insulation-resistance) | |
| 2026-10-27 | created (prod.fluke-1555-fc.function.leakage-and-capacitance) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.function.leakage-and-capacitance) | |
| 2026-10-27 | created (prod.fluke-1555-fc.function.pi-dar) | |
| 2026-10-27 | revised (prod.fluke-1555-fc.function.pi-dar) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.function.pi-dar) | |
| 2026-10-27 | created (prod.fluke-1555-fc.function.ramp-and-timer) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.function.ramp-and-timer) | |
| 2026-10-27 | created (prod.fluke-1555-fc.function.remote-operation) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.function.remote-operation) | |
| 2026-10-27 | created (prod.fluke-1555-fc.manufacturer) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.manufacturer) | |
| 2026-10-27 | created (prod.fluke-1555-fc.model) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.model) | |
| 2026-10-27 | created (prod.fluke-1555-fc.product-page) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.product-page) | |
| 2026-10-27 | created (prod.fluke-1555-fc.spec.accuracy) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.spec.accuracy) | |
| 2026-10-27 | created (prod.fluke-1555-fc.spec.battery) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.spec.battery) | |
| 2026-10-27 | created (prod.fluke-1555-fc.spec.capacitance-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.spec.capacitance-range) | |
| 2026-10-27 | created (prod.fluke-1555-fc.spec.leakage-current-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.spec.leakage-current-range) | |
| 2026-10-27 | created (prod.fluke-1555-fc.spec.live-circuit-warning) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.spec.live-circuit-warning) | |
| 2026-10-27 | created (prod.fluke-1555-fc.spec.maximum-resistance) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.spec.maximum-resistance) | |
| 2026-10-27 | created (prod.fluke-1555-fc.spec.measurement-category) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.spec.measurement-category) | |
| 2026-10-27 | created (prod.fluke-1555-fc.spec.test-voltage-accuracy) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.spec.test-voltage-accuracy) | |
| 2026-10-27 | created (prod.fluke-1555-fc.spec.test-voltage-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.spec.test-voltage-range) | |
| 2026-10-27 | created (prod.fluke-1555-fc.spec.weight) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.spec.weight) | |
| 2026-10-27 | created (prod.fluke-1555-fc.standard.en-61326) | |
| 2026-10-27 | revised (prod.fluke-1555-fc.standard.en-61326) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.standard.en-61326) | |
| 2026-10-27 | created (prod.fluke-1555-fc.standard.iec-61010-1) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.standard.iec-61010-1) | |
| 2026-10-27 | created (prod.fluke-1555-fc.standard.iec-61010-2-030) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.standard.iec-61010-2-030) | |
| 2026-10-27 | created (prod.fluke-1555-fc.standard.iec-61557) | |
| 2026-10-27 | revised (prod.fluke-1555-fc.standard.iec-61557) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.standard.iec-61557) | |
| 2026-10-27 | created (prod.fluke-1555-fc.standard.ieee-43) | |
| 2026-10-27 | revised (prod.fluke-1555-fc.standard.ieee-43) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.standard.ieee-43) | |
| 2026-10-27 | created (prod.fluke-1555-fc.title) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.fluke-1555-fc.title) |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Fluke 1555 FC." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/fluke-1555-fc/.
Test Instrument Reference, Fluke 1555 FC (Oct. 27, 2026), https://www.testinstrumentreference.com/products/fluke-1555-fc/.
@misc{etr-products-fluke-1555-fc,
title = {Fluke 1555 FC},
howpublished = {\url{https://www.testinstrumentreference.com/products/fluke-1555-fc/}},
organization = {Test Instrument Reference},
publisher = {Test Instrument Reference},
year = {2026},
note = {last substantive change 2026-10-27}
}{{cite web |title=Fluke 1555 FC |website=Test Instrument Reference |publisher=Test Instrument Reference |url=https://www.testinstrumentreference.com/products/fluke-1555-fc/ |date=2026-10-27 |access-date=}}