Doble Myrkos 2
Updated 2026-10-27
Specifications
Figures as the manufacturer states them on its product page or datasheet; each row links its data record.
- Battery run time
- 9 h
- Carrier gas autonomy
- 42 h
- Gases measured
- H2, CO, CO2, CH4, C2H2, C2H4, C2H6, O2, N2
- Ingress rating
- IP67 when closed, IP20 when open
- Lower detection limits
- H2 5 ppm; CO 1 ppm; CO2 30 ppm; CH4 1 ppm; C2H2 1 ppm; C2H4 1 ppm; C2H6 1 ppm; O2 60 ppm; N2 500 ppm
- Measurement time
- 2 min
- Operating temperature
- 0 to 50 C
Data records
- The manufacturer's page for the Myrkos 2 was read on the date given in the value. Value: 2026-10-27.
- The manufacturer lists the Myrkos 2 as a portable dissolved gas analyzer built on gas chromatography. Value: dissolved gas analyzer.
- The Myrkos 2 measures the concentration of nine fault gases dissolved in transformer insulating liquid by gas chromatography after headspace extraction with the manufacturer's shake test method.
- The Myrkos 2 analyzes free gas samples drawn from a gas relay in addition to liquid samples.
- The Myrkos 2 analyzes mineral oil, silicone liquid and natural and synthetic ester liquids.
- The Myrkos 2 is controlled from the manufacturer's PPMreport software and its results are assessed in the Myrkos View application.
- The Myrkos 2 is a product of Doble. Value: Doble.
- The manufacturer gives the model designation as Myrkos 2. Value: Myrkos 2.
- Doble maintains a product page for the Myrkos 2 on its own website, which is the page cited for this entry.
- The manufacturer states an accuracy per gas for the Myrkos 2 for gas dissolved in mineral oil, as the greater of a fixed concentration or a percentage, at a stated confidence interval. Value: greater of ±5 ppm (H2), ±1 ppm (CO, CH4, C2H2, C2H4, C2H6), ±30 ppm (CO2), ±60 ppm (O2), ±100 ppm (N2) or ±6%; 95% confidence interval.
- The manufacturer states an operating autonomy for the lithium-ion battery of the Myrkos 2 portable controller. Value: 9 h.
- The manufacturer states an operating autonomy for the helium carrier gas module of the Myrkos 2 field package. Value: 42 h.
- The manufacturer lists the gases the Myrkos 2 measures. Value: H2, CO, CO2, CH4, C2H2, C2H4, C2H6, O2, N2.
- The manufacturer states an ingress rating for the Myrkos 2 field package case when closed and when open. Value: IP67 when closed, IP20 when open.
- The manufacturer states a lower detection limit per gas for the Myrkos 2 for gas dissolved in mineral oil. Value: H2 5 ppm; CO 1 ppm; CO2 30 ppm; CH4 1 ppm; C2H2 1 ppm; C2H4 1 ppm; C2H6 1 ppm; O2 60 ppm; N2 500 ppm.
- The manufacturer states a measurement time for the Myrkos 2. Value: 2 min.
- The manufacturer states an operating temperature range for the Myrkos 2. Value: 0 to 50 C.
- The manufacturer states a repeatability per gas for the Myrkos 2 for gas dissolved in mineral oil, as the greater of a fixed concentration or a percentage. Value: greater of ±2 ppm (H2, CO, CH4, C2H2, C2H4, C2H6), ±30 ppm (CO2), ±60 ppm (O2), ±100 ppm (N2) or ±2%; 95% confidence interval.
- The manufacturer states a top of range per gas for the Myrkos 2 for gas dissolved in mineral oil. Value: 60,000 ppm for H2, CO, CO2, CH4, C2H2, C2H4 and C2H6; 100,000 ppm for O2 and N2.
- The technical specifications state the shake test method of the Myrkos 2 is a variation of ASTM D3612-02 Method C and is also described in IEC 60567, with no edition given for the latter. Value: ASTM D3612-02 Method C; IEC 60567.
- The technical specifications name IEC 61326-1 and EN 55011 as the EMI and EMC requirements of the Myrkos 2, with no edition given. They also name FCC part 15 Subpart B and ICES-003. Value: IEC 61326-1; EN 55011; FCC part 15 Subpart B; ICES-003.
- The manufacturer states the Myrkos View application assesses transformer condition levels against IEEE C57.104-2008. Value: IEEE C57.104-2008.
- The technical specifications name IEC/EN 61010-1 for safety and IEC 60529 for the ingress rating of the Myrkos 2, with no edition given. Value: IEC/EN 61010-1; IEC 60529.
- The catalog name of the model is written Doble Myrkos 2. Value: Doble Myrkos 2.
Sources
- Doble datasheet, Myrkos 2 Field Package Technical Specifications (073-MSDOC-Rev01-EN, 02/2026), web page edition, Doble. Held as: Public page. Publisher page
- Doble product page, Myrkos 2 - Doble Engineering Company, web page edition, Doble. Held as: Public page. Publisher page
Changelog (48 entries)
| Date | Revision | Change |
|---|---|---|
| 2026-10-27 | created (prod.doble-myrkos-2.checked) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.checked) | |
| 2026-10-27 | created (prod.doble-myrkos-2.class) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.class) | |
| 2026-10-27 | created (prod.doble-myrkos-2.function.dissolved-gas-analysis) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.function.dissolved-gas-analysis) | |
| 2026-10-27 | created (prod.doble-myrkos-2.function.gas-phase-samples) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.function.gas-phase-samples) | |
| 2026-10-27 | created (prod.doble-myrkos-2.function.liquid-types) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.function.liquid-types) | |
| 2026-10-27 | created (prod.doble-myrkos-2.function.software) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.function.software) | |
| 2026-10-27 | created (prod.doble-myrkos-2.manufacturer) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.manufacturer) | |
| 2026-10-27 | created (prod.doble-myrkos-2.model) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.model) | |
| 2026-10-27 | created (prod.doble-myrkos-2.product-page) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.product-page) | |
| 2026-10-27 | created (prod.doble-myrkos-2.spec.accuracy) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.spec.accuracy) | |
| 2026-10-27 | created (prod.doble-myrkos-2.spec.battery-run-time) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.spec.battery-run-time) | |
| 2026-10-27 | created (prod.doble-myrkos-2.spec.carrier-gas-autonomy) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.spec.carrier-gas-autonomy) | |
| 2026-10-27 | created (prod.doble-myrkos-2.spec.gases-measured) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.spec.gases-measured) | |
| 2026-10-27 | created (prod.doble-myrkos-2.spec.ingress-rating) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.spec.ingress-rating) | |
| 2026-10-27 | created (prod.doble-myrkos-2.spec.lower-detection-limits) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.spec.lower-detection-limits) | |
| 2026-10-27 | created (prod.doble-myrkos-2.spec.measurement-time) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.spec.measurement-time) | |
| 2026-10-27 | created (prod.doble-myrkos-2.spec.operating-temperature) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.spec.operating-temperature) | |
| 2026-10-27 | created (prod.doble-myrkos-2.spec.repeatability) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.spec.repeatability) | |
| 2026-10-27 | created (prod.doble-myrkos-2.spec.top-of-range) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.spec.top-of-range) | |
| 2026-10-27 | created (prod.doble-myrkos-2.standard.astm-d3612) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.standard.astm-d3612) | |
| 2026-10-27 | created (prod.doble-myrkos-2.standard.emc) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.standard.emc) | |
| 2026-10-27 | created (prod.doble-myrkos-2.standard.ieee-c57-104) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.standard.ieee-c57-104) | |
| 2026-10-27 | created (prod.doble-myrkos-2.standard.safety) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.standard.safety) | |
| 2026-10-27 | created (prod.doble-myrkos-2.title) | |
| 2026-10-27 | review_status unreviewed -> software_reviewed (prod.doble-myrkos-2.title) |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Doble Myrkos 2." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/doble-myrkos-2/.
Test Instrument Reference, Doble Myrkos 2 (Oct. 27, 2026), https://www.testinstrumentreference.com/products/doble-myrkos-2/.
@misc{etr-products-doble-myrkos-2,
title = {Doble Myrkos 2},
howpublished = {\url{https://www.testinstrumentreference.com/products/doble-myrkos-2/}},
organization = {Test Instrument Reference},
publisher = {Test Instrument Reference},
year = {2026},
note = {last substantive change 2026-10-27}
}{{cite web |title=Doble Myrkos 2 |website=Test Instrument Reference |publisher=Test Instrument Reference |url=https://www.testinstrumentreference.com/products/doble-myrkos-2/ |date=2026-10-27 |access-date=}}