Doble M4100

Updated 2026-10-27

Doble M4100, power factor test set
Image: Doble, from its product page (www.doble.com)

Specifications

Figures as the manufacturer states them on its product page or datasheet; each row links its data record.

Operating temperature
-20 C to +50 C
Output power
3 kVA
Output voltage
0 to 12 kV ac
Weight
45.5 kg

Data records

  • The manufacturer's page for the M4100 was read on the date given in the value. Value: 2026-10-27. Source: Doble product page, web page edition. Verified 2026-10-27. Record prod.doble-m4100.checked
  • The manufacturer lists the M4100 as a power factor and tan-delta instrument for high-voltage apparatus. Value: power factor test set. Source: Doble product page, web page edition. Verified 2026-10-27. Record prod.doble-m4100.class
  • The M4100 measures single-phase excitation current and performs capacitor bank tests. Source: Doble product page, web page edition. Verified 2026-10-27. Record prod.doble-m4100.function.excitation-current
  • The M4100 generates its test signal from an internal waveform generator and applies line frequency modulation, which the manufacturer describes as reducing electrostatic interference. Source: Doble product page, web page edition. Verified 2026-10-27. Record prod.doble-m4100.function.interference-suppression
  • The M4100 measures the power factor, tan delta and capacitance of insulation in high-voltage apparatus. Source: Doble product page, web page edition. Verified 2026-10-27. Record prod.doble-m4100.function.power-factor
  • The M4100 is operated from a computer running the manufacturer's test assistant software, which also stores and analyzes the results. Source: Doble product page, web page edition. Verified 2026-10-27. Record prod.doble-m4100.function.software-control
  • The M4100 performs turns ratio and leakage reactance (short-circuit impedance) tests with the accessories the manufacturer lists for it. Source: Doble product page, web page edition. Verified 2026-10-27. Record prod.doble-m4100.function.turns-ratio-and-leakage-reactance
  • The M4100 is a product of Doble. Value: Doble. Source: Doble product page, web page edition. Verified 2026-10-27. Record prod.doble-m4100.manufacturer
  • The manufacturer gives the model designation as M4100. Value: M4100. Source: Doble product page, web page edition. Verified 2026-10-27. Record prod.doble-m4100.model
  • Doble maintains a product page for the M4100 on its own website, which is the page cited for this entry. Source: Doble product page, web page edition. Verified 2026-10-27. Record prod.doble-m4100.product-page
  • The manufacturer states an AC input supply range for the M4100. Value: 95 to 264 V AC, 47 to 63 Hz; 16 A max at 110 V, 10 A max at 220 V. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.spec.ac-input
  • The manufacturer states an operating temperature range for the M4100 instrument. Value: -20 C to +50 C. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.spec.operating-temperature
  • The manufacturer states the output current of the M4100 by duty period at its reference voltage. Value: continuous at 100 mA at 10 kV; 30 minutes at 200 mA at 10 kV; 4 minutes at 300 mA at 10 kV. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.spec.output-current
  • The manufacturer states an output power for the M4100. Value: 3 kVA. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.spec.output-power
  • The manufacturer states an AC output voltage range for the M4100. Value: 0 to 12 kV ac. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.spec.output-voltage
  • The manufacturer states a power factor and tan delta measurement range and a guaranteed accuracy for the M4100. Value: 0 to ±100.00% PF; guaranteed accuracy ±1% of reading, ±0.04% PF/tan delta (entire range); typical accuracy < ±0.005%. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.spec.power-factor-range-accuracy
  • The manufacturer states a test current measurement range, resolution and accuracy for the M4100. Value: 0 to 5.0 A, resolution 0.1 μA, accuracy ±1% of reading, ±1 μA. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.spec.test-current-range
  • The manufacturer states a test frequency range for the M4100, generated independent of the input signal. Value: 45 to 70 Hz, resolution 0.1 Hz, accuracy ±1% of reading. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.spec.test-frequency
  • The manufacturer states a test voltage range, resolution and accuracy for the M4100. Value: 25 V to 12 kV, resolution 1 V, accuracy ±1% of reading. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.spec.test-voltage-range
  • The manufacturer states a weight for the M4100 instrument. Value: 45.5 kg. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.spec.weight
  • The technical specifications name FCC Part 15 Class A as the emissions requirement the M4100 is designed to for the USA. For Europe and Australia they name EN 55011 and AS/NZS CISPR 11, with the editions held in the value. Value: FCC 47 CFR Part 15 Class A; EN 55011:1998/A1:1999/A2:2002 Group 1 Class A; AS/NZS CISPR 11:2004 Class A. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.standard.emc-emissions
  • The technical specifications name EN 61326:1997 and the IEC 61000-4 series as the immunity requirements the M4100 is designed to, and ANSI/IEEE C37.90.1 for surge withstand capability with no edition given. Value: EN 61326:1997/A1:1998/A2:2001/A3:2003; IEC 61000-4-2/3/4/5/6/11; ANSI/IEEE C37.90.1. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.standard.emc-immunity
  • The technical specifications state the M4100 is designed to EN 61010-1:2001 (second edition) for safety. Value: EN 61010-1:2001. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.standard.en-61010-1
  • The technical specifications name the IEC 60068-2 series for dry heat, cold, damp heat, shock and vibration and ASTM D999.75 for transport shock as the environmental and mechanical tests the M4100 is designed to. Value: IEC 60068-2-2; IEC 60068-2-1; IEC 60068-2-30; IEC 60068-2-27; IEC 60068-2-6; ASTM D999.75. Source: Doble datasheet, web page edition. Verified 2026-10-27. Record prod.doble-m4100.standard.environmental
  • The catalog name of the model is written Doble M4100. Value: Doble M4100. Source: Doble product page, web page edition. Verified 2026-10-27. Record prod.doble-m4100.title

Sources

  • Doble datasheet, M4100 4th Gen Technical Specifications, web page edition, Doble. Held as: Public page. Publisher page
  • Doble product page, M4100 High Voltage Apparatus Tester, web page edition, Doble Engineering. Held as: Public page. Publisher page
Changelog (53 entries)
DateRevisionChange
2026-10-27created (prod.doble-m4100.checked)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.checked)
2026-10-27created (prod.doble-m4100.class)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.class)
2026-10-27created (prod.doble-m4100.function.excitation-current)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.function.excitation-current)
2026-10-27created (prod.doble-m4100.function.interference-suppression)
2026-10-27revised (prod.doble-m4100.function.interference-suppression)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.function.interference-suppression)
2026-10-27created (prod.doble-m4100.function.power-factor)
2026-10-27revised (prod.doble-m4100.function.power-factor)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.function.power-factor)
2026-10-27created (prod.doble-m4100.function.software-control)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.function.software-control)
2026-10-27created (prod.doble-m4100.function.turns-ratio-and-leakage-reactance)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.function.turns-ratio-and-leakage-reactance)
2026-10-27created (prod.doble-m4100.manufacturer)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.manufacturer)
2026-10-27created (prod.doble-m4100.model)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.model)
2026-10-27created (prod.doble-m4100.product-page)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.product-page)
2026-10-27created (prod.doble-m4100.spec.ac-input)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.spec.ac-input)
2026-10-27created (prod.doble-m4100.spec.operating-temperature)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.spec.operating-temperature)
2026-10-27created (prod.doble-m4100.spec.output-current)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.spec.output-current)
2026-10-27created (prod.doble-m4100.spec.output-power)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.spec.output-power)
2026-10-27created (prod.doble-m4100.spec.output-voltage)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.spec.output-voltage)
2026-10-27created (prod.doble-m4100.spec.power-factor-range-accuracy)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.spec.power-factor-range-accuracy)
2026-10-27created (prod.doble-m4100.spec.test-current-range)
2026-10-27revised (prod.doble-m4100.spec.test-current-range)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.spec.test-current-range)
2026-10-27created (prod.doble-m4100.spec.test-frequency)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.spec.test-frequency)
2026-10-27created (prod.doble-m4100.spec.test-voltage-range)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.spec.test-voltage-range)
2026-10-27created (prod.doble-m4100.spec.weight)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.spec.weight)
2026-10-27created (prod.doble-m4100.standard.emc-emissions)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.standard.emc-emissions)
2026-10-27created (prod.doble-m4100.standard.emc-immunity)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.standard.emc-immunity)
2026-10-27created (prod.doble-m4100.standard.en-61010-1)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.standard.en-61010-1)
2026-10-27created (prod.doble-m4100.standard.environmental)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.standard.environmental)
2026-10-27created (prod.doble-m4100.title)
2026-10-27review_status unreviewed -> software_reviewed (prod.doble-m4100.title)

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Doble M4100." Test Instrument Reference. 2026-10-27. https://www.testinstrumentreference.com/products/doble-m4100/.